Altistart 01 Soft Starters Page 16 Selection Tables and Dimensions

16 Altistart 01 & U01 soft starters for asynchronous motors ATS01N1 soft starters Selection Table Single-phase motors Motor Power ATS01 Soft Starter GV Manual Starter Isolation Contactor with AC Coil Isolation Contactor with DC Coil Fast Acting Class J Fuses (1) Overload Relay (2) Voltage HP 115/ 120 V 0.25 ATS01N106FT GV2ME10 LC1D09 or LC1K06 LC1D09 or LP1K06 15 A LRD10 or LR2K0312 0.33 ATS01N109FT GV2ME14 LC1D09 or LC1K09 LC1D09 or LP1K09 25 A LRD12 or LR2K0314 0.5 ATS01N112FT GV2ME16 LC1D12 or LC1K12 LC1D12 or LP1K12 30 A LRD16 or LR2K0316 230/ 240 V 0.25 ATS01N103FT GV2ME08 LC1D09 or LC1K06 LC1D09 or LP1K06 10 A LRD08 or LR2K0310 0.33 ATS01N106FT GV2ME08 LC1D09 or LC1K06 LC1D09 or LP1K06 15 A LRD08 or LR2K0310 0.5 ATS01N106FT GV2ME10 LC1D09 or LC1K06 LC1D09 or LP1K06 15 A LRD10 or LR2K0312 0.75 - 1 ATS01N109FT GV2ME14 LC1D09 or LC1K09 LC1D09 or LP1K09 25 A LRD12 or LR2K0314 1.5 ATS01N112FT GV2ME16 LC1D12 or LC1K12 LC1D12 or LP1K12 30 A LRD16 or LR2K0316 2 ATS01N112FT GV2ME16 LC1D12 35 A LRD16 Three-phase motors Motor Power ATS01 Soft Starter GV Manual Starter Isolation Contactor with AC Coil Isolation Contactor with DC Coil Fast Acting Class J Fuses (1) Overload Relay (2) Voltage HP kW 200/ 208 V 0.5 - ATS01N103FT GV2ME07 LC1D09 or LC1K06 LC1D09 or LP1K06 10 A LRD07 or LR2K0308 0.75 - ATS01N106FT GV2ME08 LC1D09 or LC1K06 LC1D09 or LP1K06 15 A LRD08 or LR2K0310 1 - ATS01N106FT GV2ME10 LC1D09 or LC1K06 LC1D09 or LP1K06 15 A LRD10 or LR2K0312 1.5 - 2 - ATS01N109FT GV2ME14 LC1D09 or LC1K09 LC1D09 or LP1K09 25 A LRD12 or LR2K0314 3 - ATS01N112FT GV2ME16 LC1D12 or LC1K12 LC1D12 or LP1K12 35 A LRD16 or LR2K0316 230/ 240 V 0.5 - ATS01N103FT GV2ME07 LC1D09 or LC1K06 LC1D09 or LP1K06 10 A LRD07 or LR2K0308 0.75 - ATS01N106FT GV2ME08 LC1D09 or LC1K06 LC1D09 or LP1K06 10 A LRD08 or LR2K0310 1 - ATS01N106FT GV2ME10 LC1D09 or LC1K06 LC1D09 or LP1K06 15 A LRD10 or LR2K0312 1.5 - ATS01N106FT GV2ME10 LC1D09 or LC1K06 LC1D09 or LP1K06 20 A LRD12 or LR2K0314 2 - ATS01N109FT GV2ME14 LC1D09 or LC1K09 LC1D09 or LP1K09 20 A LRD12 or LR2K0314 3 - ATS01N112FT GV2ME16 LC1D12 or LC1K12 LC1D12 or LP1K12 30 A LRD16 or LR2K0316 460/ 480 V 0.5 - ATS01N103FT GV2ME06 LC1D09 or LC1K06 LC1D09 or LP1K06 3 A LRD06 or LR2K0306 0.75 - ATS01N103FT GV2ME06 LC1D09 or LC1K06 LC1D09 or LP1K06 6 A LRD06 or LR2K0307 1 - ATS01N103FT GV2ME07 LC1D09 or LC1K06 LC1D09 or LP1K06 6 A LRD07 or LR2K0308 1.5 - ATS01N103FT GV2ME08 LC1D09 or LC1K06 LC1D09 or LP1K06 10 A LRD08 or LR2K0310 2 - ATS01N106FT GV2ME08 LC1D09 or LC1K06 LC1D09 or LP1K06 10 A LRD08 or LR2K0310 3 - ATS01N106FT GV2ME10 LC1D09 or LC1K06 LC1D09 or LP1K06 15 A LRD10 or LR2K0312 5 - ATS01N109FT GV2ME14 LC1D09 or LC1K09 LC1D09 or LP1K09 25 A LRD12 or LR2K0314 7.5 - ATS01N112FT GV2ME16 LC1D12 or LC1K12 LC1D12 or LP1K12 35 A LRD16 or LR2K0316 400 V - 0.37 ATS01N103FT GV2ME05 LC1D09 or LC1K06 LC1D09 or LP1K06 3 A LRD05 or LR2K0306 - 0.55 ATS01N103FT GV2ME06 LC1D09 or LC1K06 LC1D09 or LP1K06 6 A LRD06 or LR2K0307 - 0.75 ATS01N103FT GV2ME07 LC1D09 or LC1K06 LC1D09 or LP1K06 6 A LRD07 or LR2K0308 - 1.1 ATS01N103FT GV2ME07 LC1D09 or LC1K06 LC1D09 or LP1K06 10 A LRD07 or LR2K0308 - 1.5 ATS01N106FT GV2ME08 LC1D09 or LC1K06 LC1D09 or LP1K06 15 A LRD08 or LR2K0310 - 2.2 ATS01N106FT GV2ME10 LC1D09 or LC1K06 LC1D09 or LP1K06 15 A LRD10 or LR2K0312 - 3 ATS01N109FT GV2ME14 LC1D09 or LC1K09 LC1D09 or LP1K09 20 A LRD12 or LR2K0314 - 4 ATS01N109FT GV2ME14 LC1D09 or LC1K09 LC1D09 or LP1K09 25 A LRD14 or LR2K0316 - 5.5 ATS01N112FT GV2ME16 LC1D12 or LC1K12 LC1D12 or LP1K12 35 A LRD16 or LR2K0316 (1) Fuses are not required when using the GV manual starter with motor branch-circuit protection installed per NEC article 430. (2) Overload relay is not required when using the GV manual starter. ATS01N1 soft starters ATS01N1 torque limiting mini soft starts extend the Altistart 01 product range down into the fractional horsepower arena. They can control the starting ramp of either a single-phase motor (115 V, 230 V) or a three-phase motor (208 V, 230 V, and 460 V). The ATS01N1 is ideal for the following applications: Small conveyors for fragile goods, such as bottle conveyors Constant power machines, such as drills, where the starting torque must be limited Part Number Explanation ATS01N1 ATS01N2 ATSU01N2 pp FT LU/QN/RT LT Product Family Altistart 01 Power Range (Amps) ATS01N1 : 03, 06, 09, or 12 ATS01N2 : 06, 09, 12, 22, or 32 ATSU01N2 : 06, 09, 12, 22, or 32 Supply Voltage FT = 115 - 480 V QN = 400 V LU = 200 - 240 V RT = 460 V LT = 200 - 460 V

Previous Page
Next Page