Altistart 01 Soft Starters Page 18 Selection Tables and Dimensions

18 Altistart 01 & U01 soft starters for asynchronous motors Motor power (3-phase) ATS01 Soft Starter GV Manual Starter KM1 Isolation Contactor Fast Acting Class J Fuses (1) Overload Relay (2) Voltage HP kW 200/ 208 V 0.5 - ATS01N206LU GV2ME07 LC1D09 or LC1K06 10 A LRD07 or LR2K0308 0.75 - ATS01N206LU GV2ME08 LC1D09 or LC1K06 15 A LRD08 or LR2K0310 1 - ATS01N206LU GV2ME10 LC1D09 or LC1K06 15 A LRD10 or LR2K0312 1.5-2 - ATS01N209LU GV2ME14 LC1D09 or LC1K09 25 A LRD12 or LR2K0314 0.75 - ATS01N212LU GV2ME16 LC1D12 or LC1K12 30 A LRD16 or LR2K0316 3 - ATS01N212LU GV2ME16 LC1D12 or LC1K12 35 A LRD16 or LR2K0316 5 - ATS01N222LU GV2ME20 LC1D18 60 A LRD22 7.5 - ATS01N232LU GV2ME32 LC1D25 80 A LRD32 10 - ATS01N232LU GV2ME32 LC1D32 100 A LRD35 230/ 240 V 0.5 - ATS01N206LU GV2ME07 LC1D09 or LC1K06 10 A LRD07 or LR2K0308 0.75 - ATS01N206LU GV2ME08 LC1D09 or LC1K06 10 A LRD08 or LR2K0310 1 - ATS01N206LU GV2ME10 LC1D09 or LC1K06 15 A LRD10 or LR2K0312 1.5 - ATS01N206LU GV2ME10 LC1D09 or LC1K06 20 A LRD12 or LR2K0314 2 - ATS01N209LU GV2ME14 LC1D09 or LC1K09 20 A LRD12 or LR2K0314 3 - ATS01N212LU GV2ME16 LC1D12 or LC1K12 30 A LRD16 or LR2K0316 5 - ATS01N222LU GV2ME20 LC1D18 50 A LRD21 7.5 - ATS01N222LU GV2ME21 LC1D25 70 A LRD22 10 - ATS01N232LU GV2ME32 LC1D32 90 A LRD32 400 V - 1.1 ATS01N206QN GV2ME07 LC1D09 or LC1K06 10 A LRD07 or LR2K0308 - 1.5 ATS01N206QN GV2ME08 LC1D09 or LC1K06 15 A LRD08 or LR2K0310 - 2.2 ATS01N206QN GV2ME10 LC1D09 or LC1K06 15 A LRD10 or LR2K0312 - 3 ATS01N209QN GV2ME14 LC1D09 or LC1K09 20 A LRD12 or LR2K0314 - 4 ATS01N209QN GV2ME14 LC1D09 or LC1K09 25 A LRD14 or LR2K0316 - 5.5 ATS01N212QN GV2ME16 LC1D12 or LC1K12 35 A LRD16 or LR2K0316 - 7.5 ATS01N222QN GV2ME20 LC1D18 45 A LRD21 - 9 ATS01N222QN GV2ME21 LC1D25 60 A LRD22 - 11 ATS01N222QN GV2ME21 LC1D25 70 A LRD22 - 15 ATS01N232QN GV2ME32 LC1D32 90 A LRD32 460 V 0.5 - ATS01N206RT GV2ME06 LC1D09 or LC1K06 3 A LRD06 or LR2K0306 0.75 - ATS01N206RT GV2ME06 LC1D09 or LC1K06 6 A LRD06 or LR2K0307 1 - ATS01N206RT GV2ME07 LC1D09 or LC1K06 6 A LRD07 or LR2K0308 1.5-2 - ATS01N206RT GV2ME18 LC1D09 or LC1K06 10 A LRD08 or LR2K0310 3 - ATS01N206RT GV2ME10 LC1D09 or LC1K06 15 A LRD10 or LR2K0312 5 - ATS01N209RT GV2ME14 LC1D09 or LC1K09 25 A LRD12 or LR2K0314 7.5 - ATS01N212RT GV2ME16 LC1D12 or LC1K12 35 A LRD16 or LR2K0316 10 - ATS01N222RT GV2ME20 LC1D18 45 A LRD21 15 - ATS01N222RT GV2ME21 LC1D25 70 A LRD22 20 - ATS01N232RT GV2ME32 LC1D32 90 A LRD32 (1) Fuses are not required when using the GV manual starter with motor branch-circuit protection installed per NEC article 430. (2) Overload relay is not required when using the GV manual starter. ATS01N2 & ATSU01N2 soft starters Selection Table ATS01N2 & ATSU01N2 soft starters The ATS01N2 pp LU/QN/RT and ATSU01N2 pp LT soft starters control the starting and stopping ramps of three-phase motors ranging from 0.5 to 20 HP (0.75 to 15 kW), and have a motor voltage range of 208 V to 460 V. The ATSU01N2 pp LT soft starter features the same specifications as the ATS01N2 pp LU/QN/RT, with the added benefits of the Tesys U-Line motor starter. The ATS01N2 and ATSU01N2 are compatible with these common motor voltages: 0.5 to 10 HP @ 200/208 V 0.5 to 10 HP @ 230/240 V 1.1 to 15 kW @ 400 V 0.5 to 20 HP @ 460 V Part Number Explanation ATS01N1 ATS01N2 ATSU01N2 pp FT LU/QN/RT LT Product Family Altistart 01 Power Range (Amps) ATS01N1 : 03, 06, 09, or 12 ATS01N2 : 06, 09, 12, 22, or 32 ATSU01N2 : 06, 09, 12, 22, or 32 Supply Voltage FT = 115 - 480 V QN = 400 V LU = 200 - 240 V RT = 460 V LT = 200 - 460 V

Previous Page
Next Page