Altistart 22 Enclosed Altistart 22 Soft Starters Page 10 Specifications

10 Altistart 22 soft starters for asynchronous motors I/O & Control Specifications I/O & Control specifications ATS22 ppp S6U control terminals ATS22 ppp S6 & ATS22 ppp Q control terminals 110 V ac with 110 V ac logic inputs 230 V ac with 24 V dc logic input Terminal Function Characteristics Terminal Function Characteristics CL1 ATS22 control power supply 110 V ac +10% 110 V ac -15% CL1 ATS22 control power supply 230 V ac +10% 220 V ac -15% CL2 R1B Relay 1 normally closed Max switching capability: 5 A- 250 V ac or 30 V dc on resistive load ( p.f. =1) 2 A-250 V ac or 30 V dc on inductive load ( p.f.=0.4) Minimimal commutation capability: 100 mA 12 V dc R1B Relay 1 normally closed Max switching capability: 5 A- 250 V ac or 30 V dc on resistive load ( p.f. =1) 2 A-250 V ac or 30 V dc on inductive load ( p.f.=0.4) Minimimal commutation capability: 100 mA 12 V dc R1C Relay 1 common R1C Relay 1 common R1A Relay 1 normally open R1A Relay 1 normally open R2B Relay 2 normally closed R2B Relay 2 normally closed R2C Relay 2 common R2C Relay 2 common R2A Relay 2 normally open R2A Relay 2 normally open LI1 Logic input 1 3 x 110 V logic inputs with 20 k & impedance Umax = 121 Vac, Imax = 5 mA State 1: U>79 V - I>2 mA State 0: U<20 V - I<15 mA Turn on/off time delay: Hardware: <15 ms Software: <70-85 ms (anti bounce) LI1 Logic input 1 3 x 24 V logic inputs with 4.3 k & impedance Umax = 30 V, Imax = 8 mA State 1: U>11 V - I>5 mA State 0: U<5 V - I<2 mA The 24 V power supply is limited to 42 mA (for both internal and external use). 24 V dc accuracy: 24 V 6 V dc Turn on/off time delay: Hardware: <15 ms Software: <70-85 ms (anti bounce) LI2 Logic input 2 LI2 Logic input 2 LI3 Logic input 3 LI3 Logic input 3 NC Not connected +24 V dc Float 24 Vdc(+) (1) COM Common 110 Vac COM Float 24 Vdc(-) PTC1 PTC (+) PTC probe connection: Total PTC22 PTC (-) resistance of the probe circuit: 750 & at 77 F (25 C) PTC1 PTC (+) PTC probe connection: PTC2 PTC (-) Total resistance of the probe circuit: 750 & at 77 F (25 C) PTC22 PTC (-) PTC2 PTC (-) t Ground (shield) t Ground (shield) (1) 24 Vdc current is limited to 42 mA 10 %. (2) The voltage is 11.8 V 0.5 V when the communication is running, but not loaded externally. Maximum output current is 100 mA. Electrical specifications Shorting contactor Embedded Three-phase supply voltage 208 V -15% to 600 V +10% Input frequency Automatic sensing: 50 Hz to 60 Hz frequency (-5% to +5%) Current range 17 A to 590 A Control voltage power requirements ATS22...S6U = 110 V ac (-15% to +10%) or ATS22...S6 = 220 V ac (-15% to +10%) Logic input voltage ATS22...S6U = 110 V ac (-15% to +10%) or ATS22...S6 = 24 V dc (6 V dc) 1 PTC probe input 750 & at 77 F (25 C), tripping between 2600 & and 3100 & Logic inputs 3; "LI1" = run enable, "LI2" and "LI3" are prorammable ATS22...S6U = 110 V ac or ATS22...S6 = 24 V dc Relay outputs 2 programmable Form C relays Normally Open/Normally Closed (N.O./N.C.), maximum switching = 8 A under 230 V ac or V dc I/O connectors Removable plug

Previous Page
Next Page