Altistart 22 Enclosed Altistart 22 Soft Starters Page 30 Enclosed Altistart 22

30 Altistart 22 soft starters for asynchronous motors UL Type 1 & Type 12/12K Selection Table 9 Class Controller class 8638 = Fusible disconnect 8639 = Circuit breaker disconnect Type Controller style 22F = Altistart 22 with Molded Case Switch and Class J Fuse Block 22T = Altistart 22 with PowerPact Motor Circuit Protector 22U = Altistart 22 with PowerPact Thermal-magnetic Circuit Breaker Horsepower rating Enclosure type G = UL Type 1 general purpose A = UL Type 12K industrial use, dust/drip tight H = UL Type 3R outdoor use Voltage 2 = 208 V ac 4 = 460 V ac 3 = 230 V ac 5 = 575 V ac Mods Power circuit options B = Basic shunt trip S = Full-featured shunt trip N = Non-reversing isolation R = Reversing isolation Y = Integral full-voltage bypass Control options A06 = Start-stop pushbuttons B06 = Forward-off-reverse C06 = Hand-off-auto (HOA) selector switch D06 = Stop-run selector switch E06 = Hand-auto selector switch/ start-stop pushbuttons Pilot device options A07 = Run light (red), off light (green) B07 = Push-to-test run light (red), push to-test off light (green) C07 = Run light (red), off light (green), tripped light/reset (yellow) D07 = PTT run light (red), PTT off light (green), tripped light/reset (yellow) Metering options B08 = Elapsed run time meter Miscellaneous options * The complete list of Miscellaneous options is located on pages 32 & 33. - 1 2 3 4 5 6 7 8 9 H = 30 hp J = 40 hp K = 50 hp L = 60 hp M = 75 hp N = 100 hp P = 125 hp A = 3 hp B = 5 hp C = 7.5 hp D = 10 hp E = 15 hp F = 20 hp G = 25 hp Q = 150 hp R = 200 hp S = 250 hp T = 300 hp U = 350 hp W = 400 hp X = 500 hp 8639 22U C G 4 B A06 A07 B08 A10 - 1 2 3 4 5 6 7 8 UL Type 1 and Type 12/12K enclosures Standard duty ratings Input Voltage 60 Hz Horsepower Rating Enclosed 22 Catalog Number (1, 2, 3) Full Load Current Maximum Total Dissipated Power at Rated Load (4,5) Altistart 22 Catalog Number V ac HP A W 208 V 3 22 f A p 2 10.6 65.7 ATS22D17S6U 5 22 f B p 2 16.7 71.8 ATS22D32S6U 7.5 22 f C p 2 24.2 75 ATS22D32S6U 10 22 f D p 2 30.8 81.8 ATS22D47S6U 15 22 f E p 2 46.2 95.4 ATS22D62S6U 20 22 f F p 2 59.4 106.7 ATS22D75S6U 25 22 f G p 2 74.8 112 ATS22D88S6U 30 22 f H p 2 88 149 ATS22C11S6U 40 22 f J p 2 114 182.8 ATS22C14S6U 50 22 f K p 2 143 221.3 ATS22C17S6U 60 22 f L p 2 169 252.6 ATS22C21S6U 75 22 f M p 2 211 307.1 ATS22C25S6U 100 22 f N p 2 273 418.3 ATS22C32S6U 125 22 f P p 2 343 533 ATS22C41S6U 150 22 f Q p 2 395 563 ATS22C48S6U 230 V 5 22 f B p 3 15.2 66.5 ATS22D17S6U 7.5 22 f C p 3 22 74.2 ATS22D32S6U 10 22 f D p 3 28 76.5 ATS22D32S6U 15 22 f E p 3 42 94 ATS22D47S6U 20 22 f F p 3 54 101.4 ATS22D62S6U 25 22 f G p 3 68 112.8 ATS22D75S6U 30 22 f H p 3 80 115.6 ATS22D88S6U 40 22 f J p 3 104 163.7 ATS22C11S6U 50 22 f K p 3 130 199.9 ATS22C14S6U 60 22 f L p 3 154 232.9 ATS22C17S6U 75 22 f M p 3 192 273.1 ATS22C21S6U 100 22 f N p 3 248 354.4 ATS22C25S6U 125 22 f P p 3 312 481.6 ATS22C32S6U 150 22 f Q p 3 360 562.3 ATS22C41S6U 200 22 f R p 3 480 691.3 ATS22C59S6U (1) f may be F, T or U, describing the controller style. See Table 2 on page 32. (2) p may be G or A, describing the enclosure type. See Table 2 on page 32. (3) may be B, S, N, R, or Y describing the power circuit configuration. (4) Dissipated power does not include losses of the customer-supplied power fuses. (5) For btu/hr, multiply the values by 3.413.

Previous Page
Next Page