Altistart 22 Enclosed Altistart 22 Soft Starters Page 32 Enclosed Altistart 22

32 Altistart 22 soft starters for asynchronous motors UL Type 3R Selection Table UL Type 3R and 122 F (50 C) rated enclosures Standard duty ratings Input Voltage 60 Hz Horsepower Rating Enclosed 22 Catalog Number (1, 2, 3) Full Load Current Maximum Total Dissipated Power at Rated Load (4,5) Altistart 22 Catalog Number V ac HP A W 208 V 3 22 f A p 2 10.6 50.4 ATS22D17S6U 5 22 f B p 2 16.7 53.3 ATS22D32S6U 7.5 22 f C p 2 24.2 60.1 ATS22D47S6U 10 22 f D p 2 30.8 70.2 ATS22D47S6U 15 22 f E p 2 46.2 74 ATS22D75S6U 20 22 f F p 2 59.4 83.2 ATS22D88S6U 25 22 f G p 2 74.8 118.5 ATS22C11S6U 30 22 f H p 2 88 140.3 ATS22C14S6U 40 22 f J p 2 114 164.1 ATS22C17S6U 50 22 f K p 2 143 197.8 ATS22C21S6U 60 22 f L p 2 169 236.3 ATS22C25S6U 75 22 f M p 2 211 297.8 ATS22C32S6U 100 22 f N p 2 273 376.1 ATS22C41S6U 125 22 f P p 2 343 434.8 ATS22C48S6U 230 V 5 22 f B p 3 15.2 55.1 ATS22D32S6U 7.5 22 f C p 3 22 57.5 ATS22D32S6U 10 22 f D p 3 28 68.8 ATS22D47S6U 15 22 f E p 3 42 69.7 ATS22D62S6U 20 22 f F p 3 54 85.3 ATS22D75S6U 25 22 f G p 3 68 89.1 ATS22D88S6U 30 22 f H p 3 80 127.4 ATS22C11S6U 40 22 f J p 3 104 145.5 ATS22C14S6U 50 22 f K p 3 130 181.2 ATS22C17S6U 60 22 f L p 3 154 213.4 ATS22C21S6U 75 22 f M p 3 192 250.7 ATS22C25S6U 100 22 f N p 3 248 338.9 ATS22C32S6U 125 22 f P p 3 312 438.1 ATS22C41S6U 150 22 f Q p 3 360 506.6 ATS22C59S6U (1) f may be F, T or U, describing the controller style. See Table 2 on page 32. (2) p may be G or A, describing the enclosure type. See Table 2 on page 32. (3) may be B, S, N, R, or Y describing the power circuit configuration. (4) Dissipated power does not include losses of the customer-supplied power fuses. (5) For btu/hr, multiply the values by 3.413. Class Controller class 8638 = Fusible disconnect 8639 = Circuit breaker disconnect Type Controller style 22F = Altistart 22 with Molded Case Switch and Class J Fuse Block 22T = Altistart 22 with PowerPact Motor Circuit Protector 22U = Altistart 22 with PowerPact Thermal-magnetic Circuit Breaker Horsepower rating Enclosure type G = UL Type 1 general purpose A = UL Type 12K industrial use, dust/drip tight H = UL Type 3R outdoor use Voltage 2 = 208 V ac 4 = 460 V ac 3 = 230 V ac 5 = 575 V ac Mods Power circuit options B = Basic shunt trip S = Full-featured shunt trip N = Non-reversing isolation R = Reversing isolation Y = Integral full-voltage bypass Control options A06 = Start-stop pushbuttons B06 = Forward-off-reverse C06 = Hand-off-auto (HOA) selector switch D06 = Stop-run selector switch E06 = Hand-auto selector switch/ start-stop pushbuttons Pilot device options A07 = Run light (red), off light (green) B07 = Push-to-test run light (red), push to-test off light (green) C07 = Run light (red), off light (green), tripped light/reset (yellow) D07 = PTT run light (red), PTT off light (green), tripped light/reset (yellow) Metering options B08 = Elapsed run time meter Miscellaneous options * The complete list of Miscellaneous options is located on pages 32 & 33. - 1 2 3 4 5 6 7 8 9 H = 30 hp J = 40 hp K = 50 hp L = 60 hp M = 75 hp N = 100 hp P = 125 hp A = 3 hp B = 5 hp C = 7.5 hp D = 10 hp E = 15 hp F = 20 hp G = 25 hp Q = 150 hp R = 200 hp S = 250 hp T = 300 hp U = 350 hp W = 400 hp X = 500 hp 8639 22U C G 4 B A06 A07 B08 A10 - 1 2 3 4 5 6 7 8 9

Previous Page
Next Page