Altistart 22 Enclosed Altistart 22 Soft Starters Page 33 Enclosed Altistart 22

33 Altistart 22 soft starters for asynchronous motors UL Type 3R Selection Table UL Type 3R and 122 F (50 C) rated enclosures Standard duty ratings Input Voltage 60 Hz Horsepower Rating Enclosed 22 Catalog Number (1, 2, 3) Full Load Current Maximum Total Dissipated Power at Rated Load (4,5) Altistart 22 Catalog Number V ac HP A W 460 V 10 22 f D p 4 14 60.4 ATS22D32S6U 15 22 f E p 4 21 63.5 ATS22D32S6U 20 22 f F p 4 27 75.3 ATS22D47S6U 25 22 f G p 4 34 83.3 ATS22D47S6U 30 22 f H p 4 40 95.1 ATS22D62S6U 40 22 f J p 4 52 96.6 ATS22D75S6U 50 22 f K p 4 65 101.9 ATS22D88S6U 60 22 f L p 4 77 139.9 ATS22C11S6U 75 22 f M p 4 96 155.9 ATS22C14S6U 100 22 f N p 4 124 170.4 ATS22C17S6U 125 22 f P p 4 156 208.6 ATS22C21S6U 150 22 f Q p 4 180 251.3 ATS22C25S6U 200 22 f R p 4 240 322.8 ATS22C32S6U 250 22 f S p 4 302 422.9 ATS22C41S6U 300 22 f T p 4 361 471.4 ATS22C48S6U 350 22 f U p 4 414 557.3 ATS22C59S6U 575 V 15 22 f E p 5 17 68.3 ATS22D32S6U 20 22 f F p 5 22 70.2 ATS22D32S6U 25 22 f G p 5 27 77.7 ATS22D47S6U 30 22 f H p 5 32 84.9 ATS22D47S6U 40 22 f J p 5 41 89.4 ATS22D62S6U 50 22 f K p 5 52 96.8 ATS22D75S6U 60 22 f L p 5 62 104.5 ATS22D88S6U 75 22 f M p 5 77 135.1 ATS22C11S6U 100 22 f N p 5 99 155.2 ATS22C14S6U 125 22 f P p 5 125 173.4 ATS22C17S6U 150 22 f Q p 5 144 209.5 ATS22C21S6U 200 22 f R p 5 192 240.9 ATS22C25S6U 250 22 f S p 5 242 335 ATS22C32S6U 300 22 f T p 5 289 447.7 ATS22C48S6U 400 22 f W p 5 382 541.8 ATS22C59S6U (1) f may be F, T or U, describing the controller style. See Table 2 on page 32. (2) p may be G or A, describing the enclosure type. See Table 2 on page 32. (3) may be B, S, N, R, or Y describing the power circuit configuration. (4) Dissipated power does not include losses of the customer-supplied power fuses. (5) For btu/hr, multiply the values by 3.413. Class Controller class 8638 = Fusible disconnect 8639 = Circuit breaker disconnect Type Controller style 22F = Altistart 22 with Molded Case Switch and Class J Fuse Block 22T = Altistart 22 with PowerPact Motor Circuit Protector 22U = Altistart 22 with PowerPact Thermal-magnetic Circuit Breaker Horsepower rating Enclosure type G = UL Type 1 general purpose A = UL Type 12K industrial use, dust/drip tight H = UL Type 3R outdoor use Voltage 2 = 208 V ac 4 = 460 V ac 3 = 230 V ac 5 = 575 V ac Mods Power circuit options B = Basic shunt trip S = Full-featured shunt trip N = Non-reversing isolation R = Reversing isolation Y = Integral full-voltage bypass Control options A06 = Start-stop pushbuttons B06 = Forward-off-reverse C06 = Hand-off-auto (HOA) selector switch D06 = Stop-run selector switch E06 = Hand-auto selector switch/ start-stop pushbuttons Pilot device options A07 = Run light (red), off light (green) B07 = Push-to-test run light (red), push to-test off light (green) C07 = Run light (red), off light (green), tripped light/reset (yellow) D07 = PTT run light (red), PTT off light (green), tripped light/reset (yellow) Metering options B08 = Elapsed run time meter Miscellaneous options * The complete list of Miscellaneous options is located on pages 32 & 33. - 1 2 3 4 5 6 7 8 9 H = 30 hp J = 40 hp K = 50 hp L = 60 hp M = 75 hp N = 100 hp P = 125 hp A = 3 hp B = 5 hp C = 7.5 hp D = 10 hp E = 15 hp F = 20 hp G = 25 hp Q = 150 hp R = 200 hp S = 250 hp T = 300 hp U = 350 hp W = 400 hp X = 500 hp 8639 22U C G 4 B A06 A07 B08 A10 - 1 2 3 4 5 6 7 8 9

Previous Page
Next Page