Altistart 48 Enclosed Altistart 48 Soft Starters Page 17 Speci“cations

17 Altistart 48 soft starters for asynchronous motors Electrical Specifications Electrical specifications Operating category AC-53a Conforming to IEC 60947-4-2 Three-phase supply voltage V 208 V -15% to 690 V +10% Input frequency Hz 50/60 Hz 5% (automatic), 50 Hz or 60 Hz 20% (must be set) Nominal soft starter current A 17 A to 1200 A SCRs PIV 1800 PIV Motor power HP 2 to 1200 HP (3 to 900 kW) Voltage indicated on the motor nameplate V 208 V to 690 V Soft starter control circuit supply voltage V 110 V -15% to 230 V +10%, 50/60 Hz Maximum control circuit consumption (with fans operating) For ATS48D17Y...C17Y W 30 W For ATS48C21Y...C32Y W 50 W For ATS48C41Y...M12Y W 80 W Relay output (2 configurable outputs) 3 relay outputs (R1, R2, R3), normally open contacts 1 N.O. Minimum switching capacity: 10 mA for 6 Vdc. Maximum switching capacity on inductive load: 1.8 A for 230 Vac and 30 Vdc (power factor= 0.5 and L/R=20 ms). Maximum nominal operating voltage is 400 Vac. Factory setting: R1 assigned as the fault relay (configurable) R2 assigned as the end of starting relay to control the soft start bypass relay R3 assigned as motor powered (configurable) Logic inputs LI (2 configurable inputs) 4 logic inputs: Stop, Run, LI3, LI4; Impedance: 4.3 k & , isolated + 24 V input (maximum 30 V) I max. 8 mA State 0 if V < 5 V, State 1 if V > 11 V Internal source available One 24 V output, isolated and protected against short-circuits and overloads. Accuracy 25%. Max. current 200 mA. Logic outputs LO (configurable) 2 logic outputs LO1 and LO2 with 0 V common, compatible with level 1 PLC, according to standard IEC 65A-68. + 24 V input (minimum: +12 V, maximum: + 30 V) to LO+ Maximum LO output current: 200 mA if external 24 V power supply is used Analog output AO (configurable) Current output 0-20 mA or 4-20 mA Maximum load impedance: 500 & Accuracy 5% of the maximum value Input for PTC probe Total resistance of probe circuit 750 & at 25 C (77 F), according to IEC 60 738-A Maximum I/O connection capacity 12 AWG (2.5 mm 2 ) Communication RS-485 multidrop serial link integrated in the starter, for Modbus Systems, with RJ45 connector Transmission speed: 4800, 9600 or 19200 bps Maximum number of ATS48 soft starters connected: 18 Other uses: v Connection to a remote keypad display v Connection to a PC v Connection to other buses and networks via communication options Protection Thermal Built-in, starter and motor (calculated and/or thermal protection with PTC probes) Line Protection Phase failure protection, indicated by output relay Current settings The nominal motor current, In, can be adjusted from 0.4 to 1.3 times the starter nominal current. Adjustment of the maximum starting current from 1.5 to 7 times the motor In, limited to 5 times the starter nominal current. Starting mode By torque control with starter current limited to 5 In maximum. Factory setting: 4 In for standard operation on 15 s torque ramp Stopping mode Freewheel stop Freewheel stop (factory setting) Controlled stop on torque ramp Programmable between 0.5 and 60 s (for pump applications) Braked stop Controlled dynamically by the flux Note: Power factor correction capacitors can only be used upstream of the ATS48 soft start and only powered up at the end of starting. The soft starter must be grounded to meet regulations concerning leakage currents ( d 30 mA). If the installation involves several soft starts on the same supply line, each soft starter must be grounded separately.

Previous Page
Next Page