Altistart 48 Enclosed Altistart 48 Soft Starters Page 49 Enclosed Altistart 48

49 Altistart 48 soft starters for asynchronous motors Options Enclosed Altistart 48 Class Controller class 8638 = Fusible disconnect 8639 = Circuit breaker disconnect Type Controller style 48U = Enclosed Altistart 48 Soft Starter Controller Horsepower rating Enclosure type G = UL Type 1 general purpose A = UL Type 12K industrial use, dust/drip tight H = UL Type 3R outdoor use Voltage 2 = 208 V ac 4 = 460 V ac 3 = 230 V ac 5 = 575 V ac Power circuit options S = Shunt trip coil N = Non-reversing with isolation contactor R = Reversing with isolation contactor Mods Control options A06 = Start/stop pushbuttons B06 = Forward, stop, and reverse pushbuttons C06 = Hand-off-auto (HOA) selector switch D06 = Stop-run selector switch E06 = Hand-auto selector switch, start/stop pushbuttons Pilot light clusters A07 = Run (red), off (green) B07 = Push-to-test run (red), push to-test off (green) C07 = Run (red),off (green),detected fault (yellow) D07 = Push-to-test run (red), off (green), push-to-reset fault (yellow) Metering options A08 = Ammeter B08 = Elapsed run time meter Communication cards A09 = Modbus C09 = Ethernet TCP/IP D09 = Devicenet E09 = Ethernet IP Miscellaneous options * The complete list of Miscellaneous options is located on pages 50 & 51. - 1 2 3 4 5 6 7 8 9 10 J = 40 hp K = 50 hp L = 60 hp M = 75 hp N = 100 hp P = 125 hp Q = 150 hp R = 200 hp A = 3 hp B = 5 hp C = 7.5 hp D = 10 hp E = 15 hp F = 20 hp G = 25 hp H = 30 hp S = 250 hp T = 300 hp U = 350 hp W = 400 hp X = 500 hp Z = 600 hp 9 10 8639 48U C G 4 S A06 A07 B08 A09 A10 - 1 2 3 4 5 6 7 8 Control options A06 Start/Stop push buttons Provides black start and red stop push buttons (3-wire control scheme). Rule: Not available on Power Circuit R (reversing) B06 Forward-Stop-Reverse selector switch Provides three-position selector switch to select between forward, off, and reverse. Uses 2-wire control. Rule: Available for Power Circuit R (reversing) configurations only C06 Hand-Off-Auto selector switch Provides a three-position selector switch, 2-wire control scheme. Rule: Not available on Power Circuit R (reversing) D06 Stop-Run selector switch Provides a two-position selector switch. Rule: Not available on Power Circuit R (reversing) E06 Hand-Auto selector switch and Start/Stop push buttons Provides a two-position selector switch and start/stop push buttons (3-wire control) Rule: Not available on Power Circuit R (reversing) Pilot light cluster options A07 Pilot light cluster #1 Consists of red "RUN" and green "OFF" pilot lights. Provides standard red "RUN (ON)" and green "OFF" pilot lights for status annunciation. B07 Pilot light cluster #2 Consists of red "RUN" (push-to-test) and green "OFF" (push-totest) pilot lights. Provides push-to-test type red "RUN (ON)" and standard green "OFF" pilot lights for status annunciation. C07 Pilot light cluster #3 Consists of red "RUN", green "OFF" and yellow "FAULT" pilot lights. Provides standard red "RUN (ON)" green "OFF" and yellow "FAULT" pilot lights for status annunciation. Rule: Not available with Power Circuit S (Shunt Trip) D07 Pilot light cluster #4 Consists of red "RUN (ON)" (push-to-test), green "OFF" (push-to-test) and yellow "FAULT" (push-to-reset) pilot lights. Provides push-to-test type red "RUN (ON)" standard green "OFF", and push-to-reset type yellow "FAULT" for status annunciation. Rule: Not available with Power Circuit S (Shunt Trip) Meter display options A08 Ammeter Provides a single-phase ammeter fed from the Altistart 48 analog output. Dial is in percent of device rated current. Rule: Not available on Type 3R Enclosures B08 Elapsed time meter Provides a seven-digit analog, non-resettable elapsed run time meter. Rule: Not available on Type 3R Enclosures

Previous Page
Next Page