Altistart 48 Enclosed Altistart 48 Soft Starters Page 50 Enclosed Altistart 48

50 Altistart 48 soft starters for asynchronous motors Options Enclosed Altistart 48 Class Controller class 8638 = Fusible disconnect 8639 = Circuit breaker disconnect Type Controller style 48U = Enclosed Altistart 48 Soft Starter Controller Horsepower rating Enclosure type G = UL Type 1 general purpose A = UL Type 12K industrial use, dust/drip tight H = UL Type 3R outdoor use Voltage 2 = 208 V ac 4 = 460 V ac 3 = 230 V ac 5 = 575 V ac Power circuit options S = Shunt trip coil N = Non-reversing with isolation contactor R = Reversing with isolation contactor Mods Control options A06 = Start/stop pushbuttons B06 = Forward, stop, and reverse pushbuttons C06 = Hand-off-auto (HOA) selector switch D06 = Stop-run selector switch E06 = Hand-auto selector switch, start/stop pushbuttons Pilot light clusters A07 = Run (red), off (green) B07 = Push-to-test run (red), push to-test off (green) C07 = Run (red),off (green),detected fault (yellow) D07 = Push-to-test run (red), off (green), push-to-reset fault (yellow) Metering options A08 = Ammeter B08 = Elapsed run time meter Communication cards A09 = Modbus C09 = Ethernet TCP/IP D09 = Devicenet E09 = Ethernet IP Miscellaneous options * The complete list of Miscellaneous options is located on pages 50 & 51. - 1 2 3 4 5 6 7 8 9 10 J = 40 hp K = 50 hp L = 60 hp M = 75 hp N = 100 hp P = 125 hp Q = 150 hp R = 200 hp A = 3 hp B = 5 hp C = 7.5 hp D = 10 hp E = 15 hp F = 20 hp G = 25 hp H = 30 hp S = 250 hp T = 300 hp U = 350 hp W = 400 hp X = 500 hp Z = 600 hp 9 10 8639 48U C G 4 S A06 A07 B08 A09 A10 - 1 2 3 4 5 6 7 8 Miscellaneous options Mod A10 Full voltage bypass (AC3) Provides an AC3 duty rated bypass/shorting contactor, normal/bypass selector switch, Class 20 bi-metal motor OL relay, door mounted OL reset push-button for across the line starting capability. Rule: Only available for Power Circuit N (Non-Reversing). Not available with Power Circuit S (Shunt Trip) SCR fault isolation scheme. B10 150 VA additional control power capacity Provides 150 VA additional control VA capacity for customer use. C10 Power up ON delay (start relay) Provides an electronic time delay relay adjustable from 0.1 to 60 seconds. Relay is pre-wired to inhibit start for users to set delay time upon power-up of control. D10 Emergency stop push button Provides a push-button for immediate removal of power. E10 "cUL" label Provides a Canadian Underwriters Laboratories label when required by local code requirements. Communications cards Factory installed communication features shall be available as a custom engineered option utilizing the RJ45 communications port for control and annunciation of the soft starter in "link" mode A09 Modbus Provides Modbus communications (native protocol) C09 Ethernet TCP/IP Provides Ethernet gateway communications protocol. D09 DeviceNet Provides DeviceNet gateway communications protocol. E09 Ethernet IP Provides Ethernet IP gateway communications protocol. F10 Auxiliary contacts for run mode Provides 1 Form 'C' contact rated 5 A @ 120 Vac (8501 Type R relay or equivalent) wired to terminal blocks for customer use. Contacts change state when soft starter is sending current to the motor. Controlled by the R3 relay programmed for "rnl". G10 Auxiliary contacts for full voltage bypass run mode Provides 1 Form 'C' contact rated 5 A @ 120 Vac (8501 Type R relay or equiva- lent) wired to terminal blocks for customer use. Contacts change state when motor is operated across the line with full voltage bypass starter. Rule: MOD A10 (Full Voltage Bypass) must be selected. Must use Power Circuit N or R (line isolation contactor combination). Not compatible with Power Circuit S (Shunt Trip). H10 Auxiliary contacts for auto mode Provides an auxiliary starter mode (auto) contact that will energize a relay with 1 Form 'C' contact rated 5 A @ 120 Vac (8501 Type R relay or equivalent) wired to terminal blocks for customer use. Rule: MOD C06 (Hand-Off-Auto selector switch) or E06 (Hand-Auto selector switch) must be specified. J10 Auxiliary contacts for detected fault mode Provides an auxiliary starter mode (auto) contact that will energize a relay with 1 Form 'C' contact rated 5 A @ 120 Vac (8501 Type R relay or equivalent) wired to terminal blocks for customer use. *Miscellaneous options are continued on the next page

Previous Page
Next Page