Altistart 48 Enclosed Altistart 48 Soft Starters Page 51 Enclosed Altistart 48

51 Altistart 48 soft starters for asynchronous motors Options Enclosed Altistart 48 Class Controller class 8638 = Fusible disconnect 8639 = Circuit breaker disconnect Type Controller style 48U = Enclosed Altistart 48 Soft Starter Controller Horsepower rating Enclosure type G = UL Type 1 general purpose A = UL Type 12K industrial use, dust/drip tight H = UL Type 3R outdoor use Voltage 2 = 208 V ac 4 = 460 V ac 3 = 230 V ac 5 = 575 V ac Power circuit options S = Shunt trip coil N = Non-reversing with isolation contactor R = Reversing with isolation contactor Mods Control options A06 = Start/stop pushbuttons B06 = Forward, stop, and reverse pushbuttons C06 = Hand-off-auto (HOA) selector switch D06 = Stop-run selector switch E06 = Hand-auto selector switch, start/stop pushbuttons Pilot light clusters A07 = Run (red), off (green) B07 = Push-to-test run (red), push to-test off (green) C07 = Run (red),off (green),detected fault (yellow) D07 = Push-to-test run (red), off (green), push-to-reset fault (yellow) Metering options A08 = Ammeter B08 = Elapsed run time meter Communication cards A09 = Modbus C09 = Ethernet TCP/IP D09 = Devicenet E09 = Ethernet IP Miscellaneous options * The complete list of Miscellaneous options is located on pages 50 & 51. - 1 2 3 4 5 6 7 8 9 10 J = 40 hp K = 50 hp L = 60 hp M = 75 hp N = 100 hp P = 125 hp Q = 150 hp R = 200 hp A = 3 hp B = 5 hp C = 7.5 hp D = 10 hp E = 15 hp F = 20 hp G = 25 hp H = 30 hp S = 250 hp T = 300 hp U = 350 hp W = 400 hp X = 500 hp Z = 600 hp 9 10 8639 48U C G 4 S A06 A07 B08 A09 A10 - 1 2 3 4 5 6 7 8 Miscellaneous options (continued) L10 ID engraved nameplates Provides a lamacoid nameplate, engraved with equipment designation. M10 Spare terminal blocks Provides up to (10) spare terminal blocks 'unwired' for customer use. Since Phoenix style terminal blocks will be used, extra terminal points will be provided as standard. 20 terminal points are available as standard for all control wiring (including any additional customer spare terminal points). P10 Permanent wire markers Provides a permanent sleeve type wire marker on control wiring assemblies Q10 ANSI #61 enclosure paint (custom engineered option) Provides the option to configure the enclosure paint scheme to standard ANSI #61 paint instead of ANSI #49 paint. R10 MOV/Surge arrestor (custom engineered option) Provides supplementary MOV protection using a Class 6671 SDSA3650 Surge- breaker secondary surge arrester hard-wired and factory mounted. S10 Dual motor overloads and branch circuit protection (custom engineered option) Provides dual-rated motor OLs rated equally, one-half the HP of the selected starter. Motor branch short circuit protection is provided per NEC. Maximum total current rating of the combined motors not to exceed the continuous current rating of the starter package. Rule: Available on Class 8639 circuit breaker disconnect configurations only. U10 Omit door mounted keypad display Removes the keypad display from outside the enclosure door. The keypad on the Altistart 48 can be used for programming and commissioning. Rule: Only for Type 3R size D and E enclosures. V10 OSHPD seismic qualification Provides special labels and documents to comply with the seismic requirements of the California Office of Statewide Planning and Development (OSHPD). W10 NEMA style contactors (custom engineered option) Provides horsepower rated NEMA rated contactors instead of AC3 rated IEC TeSys or F-line contactors. X10 122 F, 50 C operation Provides extended range high ambient equipment rating above 104 F (40 C) to a maximum of 122 F (50 C) without de-rating. Rule: Standard on Type 3R enclosures Y10 Seismic qualification label Provides a self-certified identification label with compliance to 2000 IBC, NFPA 5000, 2001 CBC, 1997 UBC, 1999 NBC, 1999SBC, ASCE-7 02 seismic qualification/certification. The label criteria will be uniform for all enclosed products. Enclosures shall contain additional bracing as defined by the seismic qualification/certification criteria. Rule: Not available for Enclosure Sizes A-C (wall mounted enclosures) Z10 Service Entrance Rating Provides a UL869A approved insulated ground neutral lug assembly, mounting bracket with bonded enclosure ground wire suitable for use as service entrance equipment. Rule: Service Entrance Rating is only available for Type 3R enclosures and is not available with the Model E10 (cUL Label). 610 1 100K circuit breaker rating Only available: 208 V, 125-200 hp 230 V, 150-250 hp 460 V, 300-500 hp (1) Only available for 208 V, 125 - 200 HP; 230 V, 150 - 250 HP; and 460V, 300 - 500 HP.

Previous Page
Next Page