Altivar 12 Variable Speed Drives Page 7 Specifications

7 Altivar 12 variable speed drives Electrical & environmental Environmental Specifications Vibration resistance Drive not mounted on rail 5 According to IEC/EN 60068-2-6: 1.5 mm peak from 3 to 13 Hz 1 gn from 13 to 200 Hz Shock resistance 15 gn for 11 ms according to IEC/EN 60068-2-27 Maximum ambient pollution Definition of insulation Degree 2 according to IEC/EN 61800-5-1 Environmental conditions Use IEC 60721-3-3 classes 3C3 and 3S2 Relative humidity % 595 non condensing, no dripping water, according to IEC 60068-2-3 Ambient air temperature * Operation ATV12H018F1, H037F1 ATV12H018M2H075M2 ATV12H018M3H075M3 ATV12P ppppp C - 10+ 40 without derating Up to + 60, with the protective blanking cover removed and current derating of 2% per ad- ditional degree ATV12H075F1 ATV12HU15M2, HU22M2 ATV12HU15M3HU40M3 C - 10+ 50 without derating Up to + 60, with the protective blanking cover removed and current derating of 2% per ad- ditional degree Storage ATV12 ppppppC - 25+ 70 *Note: UL rating is for up to 40 C. Higher temperature ratings listed above are for non-UL applications only. Maximum operating altitude ATV12 pppppp m 1000 without derating ATV12 pppp F1 m Up to 2000 for single-phase networks and corner grounded distribution networks, with current derating of 1% per additional 100 m ATV12 pppp M2 m Up to 3000 meters for three-phase networks, with current derating of 1% per additional 100 m Operating position Maximum permanent angle in relation to the normal verti- cal mounting position Specifications Electrical Specifications Input power Voltage V 100 - 15% to 120 + 10% single-phase for ATV 12 pppp F1 200 - 15% to 240 + 10% single-phase for ATV 12 pppp M2 200 - 15% to 240 + 10% three-phase for ATV 12 pppp M3 Frequency Hz 5060 5% Drive output voltages V 200240 three-phase Output frequency range Hz 0.5400 Configurable switching frequency kHz Nominal switching frequency: 4 kHz without derating in continuous operation Adjustable during operation from 2 to 16 kHz Above 4 kHz in continuous operation, apply derating to the nominal drive current of: 10% for 8 kHz 20% for 12 kHz 30% for 16 kHz Above 4 kHz, the drive will reduce the switching frequency automatically in the event of exces- sive temperature rise. (1) Speed range 120 Transient overtorque 150170% of the nominal torque depending on the drive rating and the type of motor Braking torque Up to 70% of the nominal torque without resistor Up to 150% of the nominal motor torque with braking unit (optional) at high inertia Maximum transient current 150% of the nominal drive current for 60 seconds Motor control profiles Standard profile (voltage/frequency ratio) Performance profile (sensorless flux vector control) Pump/fan profile (Kn 2 quadratic ratio) Maximum length of motor cable (including tap links) Shielded cable m 50 Unshielded cable m 100 Drive noise level ATV12H018F1, H037F1 ATV12H018M2H075M2 ATV12H018M3H075M3 ATV12P ppppp dBA 0 ATV12H075F1 ATV12HU15M2, HU22M2 dBA 45 ATV12HU15M3HU40M3 dBA 50 Electrical isolation Electrical isolation between power and control (inputs, outputs, power supplies) 10 10

Previous Page
Next Page