Altivar 212 Variable Speed Drives Page 36 S-Flex enclosed variable speed drives

36 S-Flex enclosed variable speed drives Selection Tables 208/230 Vac S-Flex drives Input Voltage 60 Hz HP (1) kW Input current Output current Max. transient output current 60 s Total dissipated power at rated load S-Flex catalog number (2) Weight Frame size Power converter part number (5) A (3) A (1) A (1) W (1,4) lbs kg 208 Vac 1 0.75 3.3 4.8 5.1 184.2 SFD212CG2 52 23.587 A ATV212H075M3X 2 1.5 6.1 7.8 8.3 228.3 SFD212DG2 52 23.587 A ATV212HU15M3X 3 2.2 8.7 11 11.7 256.0 SFD212EG2 52 23.587 A ATV212HU22M3X 5 4 15.7 17.5 19.3 326.8 SFD212FG2 52 23.587 A ATV212HU40M3X 7.5 5.5 20.8 25.3 36.6 384.7 SFD212GG2 52 23.587 A ATV212HU55M3X 10 7.5 27.9 32.2 35.2 495.0 SFD212HG2 52 23.587 A ATV212HU75M3X 15 11 42.1 48.3 504.8 641.2 SFD212JG2 111 50.349 B ATV212HD11M3X 20 15 56.1 62.1 67.1 846.1 SFD212KG2 111 50.349 B ATV212HD15M3X 25 18.5 67.3 78.2 82.3 939.1 SFD212LG2 111 50.349 B ATV212HD18M3X 30 22 80.4 92 96.8 1017.6 SFD212MG2 140 63.503 C ATV212HD22M3X 40 30 113.3 120 128.7 1414.3 SFD212NG2 206 93.440 D ATV212HD30M3X 230 Vac 1 0.75 2.8 4.2 5.1 183.1 SFD212CG3 52 23.587 A ATV212H075M3X 2 1.5 5.3 6.8 8.3 226.1 SFD212DG3 52 23.587 A ATV212HU15M3X 3 2.2 7.6 9.6 11.7 252.1 SFD212EG3 52 23.587 A ATV212HU22M3X 5 4 13.5 15.2 19.3 323.5 SFD212FG3 52 23.587 A ATV212HU40M3X 7.5 5.5 18.1 22 26.6 381.0 SFD212GG3 52 23.587 A ATV212HU55M3X 10 7.5 24.4 28 35.2 489.1 SFD212HG3 52 23.587 A ATV212HU75M3X 15 11 35.7 42 50.8 630.6 SFD212JG3 111 50.349 B ATV212HD11M3X 20 15 47.6 54 67.1 829.5 SFD212KG3 111 50.349 B ATV212HD15M3X 25 18.5 58.0 68 82.3 918.3 SFD212LG3 111 50.349 B ATV212HD18M3X 30 22 69.0 80 96.8 994.1 SFD212MG3 140 63.503 C ATV212HD22M3X 40 30 93.0 104 128.7 1378.4 SFD212NG3 206 93.440 D ATV212HD30M3X (1) These power, amperage, and wattage ratings apply to: -Power converters ATV212H075 ppp to HD15 ppp (1-20 hp) operating at a switching frequency of 12 kHz, and at 40 C (104 F) ambient temperature. -Power converters ATV212HD18 ppp to HD75 ppp (25-100 hp @ 460 V) operating at a switching frequency of 8 kHz, and at 40 C (104 F) ambient temperature. For a switching frequency between 13 kHz and 16 kHz, select the next largest size drive. If the duty cycle does not exceed 60% (36 s for a 60 s cycle) this is not necessary. (2) The " p indicates that the catalog number can end in a "Y" (for an S-flex drive with full voltage bypass) or a "W" (for an S-Flex drive without bypass). (3) Select the conductor based on the input line current or the motor FLA, whichever is greater. (4) For btu/hr, multiply values by 3.413. (5) Drives shown in the table are installed in SFD212 controllers. Dimensions Frame Size W x H x D Inches mm A 8.714 x 40.375 x 7.895 221.3 x 1025 x 200.5 B 12.215 x 45.142 x 8.725 310.3 x 1146.6 x 221.6 C 12.532 x 62.006 x 10.916 318.3 x 1575 x 277.3 D 15.243 x 64.9 x 11.915 387.5 x 1648.5 x 302.7 SFD212 Product Family S-Flex p Power Range (HP) C = 1 L = 25 D = 2 M = 30 E = 3 N = 40 F = 5 P = 50 (460V only) G = 7.5 Q = 60 (460V only) H = 10 R = 75 (460V only) J = 15 S = 100 (460V only) K = 20 G Enclosure Type G = Type 1 General Purpose W Y Power circuit W = Without bypass Y = Full voltage bypass 2 3 4 Supply Voltage 2 = 208 Vac 3 = 230 Vac 4 = 460 Vac Part Number Explanation ppp Communication set-up options Miscellaneous options A06 = BACnet Card A07 = Drive input disconnect (1) B06 = LonWorks Card B07 = Line contactor (1) C06 = Metasys N2 Card S07 = Seismic certification D06 = Apogee P1 Card D07 = Full text keypad N06 = Modbus X07 = AC line reactor Options Communication set-up options Miscellaneous options A06 BACnet Card A07 Drive input disconnect B06 LonWorks Card B07 Line Contactor C06 Metasys N2 Card S07 Seismic certification D06 Apogee P1 Card D07 Full text keypad N06 Modbus X07 AC line reactor S-Flex enclosed drive, frame size A

Previous Page
Next Page