Altivar 32 Variable Speed Drives Page 14 Selection Table

14 Altivar 32 variable speed drives Selection Table Motor Line Supply Altivar 32 Power indicated on rating plate Max. line current (1), (2) Apparent power Max. prospective line (Isc) (3) Max. continuous output current (In) (4) Maximum transient current for 60 s Power dissipated at maximum output current (In) (4) Part number Frame size Weight at U1 at U2 at U2 at U2 HP kW A A kVA kA A W lbs kg Single-phase supply voltage: 200 to 240 V 50/60 Hz, with integrated EMC filter (2) (5) (6) 0.18 0.25 3.4 2.8 0.7 1 1.5 2.3 25 ATV32H018M2 A 3.5 1.59 0.37 0.5 6 5 1.2 1 3.3 5 38 ATV32H037M2 A 3.63 1.65 0.55 0.75 7.9 6.7 1.6 1 3.7 5.6 42 ATV32H055M2 A 3.63 1.65 0.75 1 10.1 8.5 2 1 4.8 7.2 51 ATV32H075M2 A 3.63 1.65 1.1 1.5 13.6 11.5 2.8 1 6.9 10.4 64 ATV32HU11M2 B 4.30 1.95 1.5 2 17.6 14.8 3.6 1 8 12 81 ATV32HU15M2 B 4.30 1.95 2.2 3 23.9 20.1 4.8 1 11 16.5 102 ATV32HU22M2 B 4.55 2.1 Three-phase supply voltage: 380 to 500 V 50/60 Hz, with integrated EMC filter (2),(5),(6) 0.37 0.5 2.1 1.6 1.4 5 1.5 2.3 27 ATV32H037N4 A 3.57 1.62 0.55 0.75 2.8 2.2 1.9 5 1.9 2.9 31 ATV32H055N4 A 3.78 1.72 0.75 1 3.6 2.7 2.3 5 2.3 3.5 37 ATV32H075N4 A 3.78 1.72 1.1 1.5 5 3.8 3.3 5 3 4.5 50 ATV32HU11N4 A 3.76 1.71 1.5 2 6.5 4.9 4.2 5 4.1 6.2 63 ATV32HU15N4 A 3.76 1.71 2.2 3 8.7 6.6 5.7 5 5.5 8.3 78 ATV32HU22N4 B 5.11 2.32 3 - 11.1 8.4 7.3 5 7.1 10.7 100 ATV32HU30N4 B 4.68 2.12 4 5 13.7 10.5 9.1 5 9.5 14.3 125 ATV32HU40N4 B 4.8 2.18 5.5 7.5 20.7 14.5 17.9 22 14.3 21.5 233 ATV32HU55N4 C 9.72 4.41 7.5 10 26.5 18.7 22.9 22 17 25.5 263 ATV32HU75N4 C 9.72 4.41 11 15 36.6 25.6 31.7 22 27.7 41.6 403 ATV32HD11N4 D 15.4 7.0 15 20 47.3 33.3 41 22 33 49.5 480 ATV32HD15N4 D 15.4 7.0 (1) Typical value for a 4-pole motor and a maximum switching frequency of 4 kHz, with no line choke for max. prospective line Isc. (2) Nominal supply voltage, min. U1, max. U2: 200 (U1) to 240 V (U2), 380 (U1) to 500 V (U2). (3) If line Isc (available short circuit current) is greater than the values in the table, add line chokes (see page 24). (4) These values are given for a nominal switching frequency of 4 kHz, for use in continuous operation. The switching frequency is adjustable from 2 to16 kHz. Above 4 kHz, derate the nominal drive current. The nominal motor current should not exceed this value. See the derating curves by following the Altivar 32 Installation Manual which can be loca. (5) Drives supplied with category C2 integrated EMC filter. This filter can be disconnected if the product is used in isolated or impedance grounded neutral electrical distribution systems. (6) Connection in compliance with EMC standards: - ATV32H ppp M2, ATV 32H037N4 to HU40N4 drives are supplied with an EMC plate. This is an integral part of the power terminals; these 2 components cannot be separated. - ATV32HU55N4 to HD15N4 drives are supplied with an EMC plate, for assembly by the customer. ATV 32H018M2 to H075M2 ATV 32H037N4 to HU15N4 ATV 32HU11M2 to HU22M2 ATV 32HU22N4 to HU40N4 ATV 32HU55N4, HU75N4 EMC plate not mounted ATV 32HD11N4, HD15N4 EMC plate not mounted

Previous Page
Next Page