Altivar 32 Variable Speed Drives Page 29 Accessories and Options

29 Altivar 32 variable speed drives Communication buses and networks Accessories & Options CANopen machine bus (1) Description No. Length Part number Weight ft m lbs kg Connection with VW3 A3 608 CANopen Daisy chain card (optimized solution for daisy chain connection to the CANopen machine bus) CANopen Daisy chain communication card (2) (3) Ports: 2 RJ45 connectors 1 - - VW3A3608 - - CANopen cordsets equipped with 2 RJ45 connectors 2 1 0.3 VW3CANCARR03 0.11 0.05 3.3 1 VW3CANCARR1 0.11 0.05 CANopen line terminator for RJ45 connector (4) 3 - - TCSCAR013M120 - - Connection via SUB-D connector with VW A3 618 CANopen card CANopen communication card (2) (3) Port: 1 x 9-way male SUB-D connector 4 - - VW3A3618 - - CANopen cable Standard cable, e marking Low smoke zero halogen Flame retardant (IEC 60332-1) 5 164 50 TSXCANCA50 10.9 4.9 328 100 TSXCANCA100 19.4 8.8 984 300 TSXCANCA300 54.2 24.6 CANopen cable Standard cable, UL certification, e marking Flame retardant (IEC 60332-2) 5 164 50 TSXCANCB50 7.9 3.6 328 100 TSXCANCB100 17.3 7.8 984 300 TSXCANCB300 48.2 21.9 CANopen cable Cable for harsh environments (5) or mobile installations, e marking Low smoke zero halogen Flame retardant (IEC 60332-1) 5 164 50 TSXCANCD50 7.7 3.5 328 100 TSXCANCD100 17.1 7.8 984 300 TSXCANCD300 47.8 21.7 CANopen IP 20 straight connector 9-way female SUB-D with line terminator which can be deactivated 6 - - TSXCANKCDF180T 0.1 0.05 IP 20 CANopen right angle connector (6) 9-way female SUB-D with line terminator which can be deactivated 6 - - TSXCANKCDF90T 0.1 0.05 (1) The Modbus serial link always uses the RJ45 communication port located on the front. If simultaneous use of the Modbus serial link and the CANopen machine bus is required, a CANopen communication card is needed. (2) The Altivar 32 drive can only accept one communication card. (3) When one of the CANopen communication cards is inserted in the Altivar 32 drive, CANopen communication via the RJ45 communication port on the front is disabled. (4) Order in multiples of 2. (5) Standard environment: - No particular environmental constraints - Operating temperature between 41 F and 140 F (5C and 60C) - Fixed installation Harsh environment: - Resistance to hydrocarbons, industrial oils, detergents, solder splashes - Relative humidity up to 100% - Saline atmosphere - Operating temperature between 14 F and 158 F (-10C and +70C) - Significant temperature variations (6) Incompatible with side-by-side mounting. (7) Please refer to the "M238 logic controller" and "M258 logic controller" catalogs. (8) Cable dependent on the type of controller or PLC; please refer to the corresponding catalog. VW3A3608 2 1 1 2 3 Modicon M238 PLC/Modicon M258 PLC (7) Altivar 32 + VW3A3608 card CANopen machine bus (8) Optimized solution for daisy chain connection to the CANopen machine bus VW3A3618 Example of connection to the CANopen machine bus via SUB-D connector 5 4 4 5 6 Altivar 32 + VW3A3618 card Modicon M238/Modicon M258 (7) CANopen machine bus (8)

Previous Page
Next Page