66 Altivar 61 variable speed drives Selection table E-Flex Miscellaneous Option A09 = Line Reactor, 5% B09 = Line Contactor C09 = 3-15PSI Transducer D09 = Omit Keyboard E09 = Smoke Purge (Fireman's override) F09 = Profibus H09 = I/O Extension Card, 0-20mA J09 = 0-10Vdc Differential input K09 = cUL Listing certification L09 = LonWorks M09 = Modbus Unitelway O09 = Apogee P1 P09 = Metasys N2 Q09 = Ethernet TCP/IP R09 = BACnet S09 = End Damper Control T09 = Service entrance U09 = Seismic qualification V09 = Ethernet IP X09 = Line Reactor, 3% E-Flex Replace p with desired enclosure rating HP Refer- ence Code HP Ratings Control- ler Output Current Enclo- sure Frame Size Power Circuits Variable Torque - Duty Rating (110% current Limit) Power Circuit W Power Circuit Y 208V, 60 Hz C 1 4.6 A C C p 2VW C p 2VY D 2 7.5 A D p 2VW D p 2VY E 3 10.6 A E p 2VW E p 2VY F 5 16.7 A F p 2VW F p 2VY G 7.5 24.2 A D G p 2VW G p 2VY H 10 30.8 A H p 2VW H p 2VY J 15 46.2 A E J p 2VW J p 2VY K 20 59.4 A K p 2VW K p 2VY L 25 74.8 A L p 2VW L p 2VY M 30 88 A F M p 2VW M p 2VY N 40 114 A N p 2VW N p 2VY P 50 143 A P p 2VW P p 2VY 230 V, 60 Hz C 1 4.2 A C C p 3VW C p 3VY D 2 6.8 A D p 3VW D p 3VY E 3 9.6 A E p 3VW E p 3VY F 5 15.2 A F p 3VW F p 3VY G 7.5 22 A D G p 3VW G p 3VY H 10 28 A H p 3VW H p 3VY J 15 42 A E J p 3VW J p 3VY K 20 54 A K p 3VW K p 3VY L 25 68 A L p 3VW L p 3VY M 30 80 A F M p 3VW M p 3VY N 40 104 A N p 3VW N p 3VY P 50 130 A P p 3VW P p 3VY 460 V, 60 Hz C 1 2.1 A C C p 4VW C p 4VY D 2 3.4 A D p 4VW D p 4VY E 3 4.8 A E p 4VW E p 4VY F 5 7.6 A F p 4VW F p 4VY G 7.5 11 A G p 4VW G p 4VY H 10 14 A H p 4VW H p 4VY J 15 21 A J p 4VW J p 4VY K 20 27 A K p 4VW K p 4VY L 25 34 A L p 4VW L p 4VY M 30 40 A E M p 4VW M p 4VY N 40 52 A N p 4VW N p 4VY P 50 65 A P p 4VW P p 4VY Q 60 77 A F Q p 4VW Q p 4VY R 75 96 A R p 4VW R p 4VY S 100 124 A S p 4VW S p 4VY Class Combination device 8839 = Circuit breaker disconnect Type Design EFD = E-Flex controller Horsepower rating C = 1 L = 25 D = 2 M = 30 E = 3 N = 40 F = 5 P = 50 G = 7.5 Q = 60 (460 V only) H = 10 R = 75 (460 V only) J = 15 S = 100 (460 V only) K = 20 Enclosure environmental rating A = Type 12K G = Type 1 H = 3R Replace p with desired enclosure rating Voltage code 2 = 208 V, 60 Hz 3 = 230 V, 60 Hz 4 = 460 V, 60 Hz Application type V = Variable torque Power circuit type W = Without bypass Y = Bypass Mods Control Option A07 = Hand-Off-Auto, Speed Potentiometer B07 = Hand-Off-Auto, Start-Stop, Speed Potientiometer C07 = Start-Stop, Speed Potentiometer D07 = Hand-Off-Comm, Speed Potentiometer E07 = Hand-Off-Comm, Start-Stop, Speed Potentiometer N07 = None Light Option A08 = Red Power On, Green AFC Run, Yellow AFC Detected Fault, Yellow Bypass B08 = Red Power On, Green AFC Run, Yellow AFC Detected Fault, Yellow Bypass C08 = Red Power On, Green AFC Run, Yellow AFC Detected fault N08 = No lights 1 2 3 4 5 6 7 8 8839 EFD N G 4 V W A07 A08 A09 1 2 3 4 5 6 7 8 9 9 10

Previous Page
Next Page