Altivar 61 And Altivar 61 Plus Variable Speed Drives Page 69 E-Flex

69 Altivar 61 variable speed drives Options E-Flex Miscellaneous Options A09 Line Reactor Factory-mounted line reactor within enclosure. Standard = 3% DC Choke Mod A09 = 5% Line Reactor B09 Line Contactor A line contactor can be added between the circuit breaker and the drive (Type 1 and 12K only). C09 3-15 PSI Transducer Allows the controller to follow a user-supplied 3-15 PSI input. D09 Omit Door-Mounted Graphic Display Terminal The graphic display terminal is not supplied. The user must buy the terminal as a separate device to program the drive. E09 Smoke Purge Provides a smoke purge operating mode controlled by a user-supplied 120 Vac signal wired to customer's terminal block. F09 Profibus Serial Communication Provides a factory-installed plug-in Profibus card, VW3A3307. H09 I/O Extension 0-20 mA analog output for customer use. Factory programmed for motor frequency. Includes I/O extension card VW3A3202. Reassignable x-y range with keypad display. Also includes logic inputs, logic outputs, analog inputs, analog outputs, configurable relay outputs, PTC probe input, and frequency control input. J09 0-10 Vdc Auto Speed Reference Provides for a 0-10 Vdc user-supplied auto speed reference signal to the AI2 input. K09 cUL Listing Provides Canadian cUL certification when required by local code require- ments. L09 LonWorks Serial Communication Provides a factory installed LonWorks card, VW3A3312. M09 Modbus Serial Communication Provides a factory installed plug-in Modbus card VW3A3303. P09 Metasys N2 Serial Communication Provides a factory installed plug-in Metasys N2 card VW3A3313. O09 P1 Serial Communication Provides a factory installed plug-in Apogee P1 card VW3A3314. Q09 Ethernet Serial Communication Provides a factory installed plug-in Ethernet card VW3A3310D. R09 BACnet Serial Communication Provides a factory installed plug-in BACnet card VW3A3315. S09 End Damper Control Provides a circuit to delay drive operation until the damper is fully open. T09 Service Entrance Rating Provides a factory-installed insulated ground neutral assembly with ground wire and label for use as service entrance rated equipment. U09 Seismic Qualified Provides a certification label and hardware qualified to seismic rating ICC ES AC156 acceptance criteria test protocol with an importance factor of 1.5. V09 Ethernet IP Provides a factory installed plug-in Ethernet IP card VW3A3316. X09 Line Reactor Factory-mounted line reactor within enclosure Standard = 3% DC Choke Mod X09 = 3% Line Reactor

Previous Page
Next Page