Altivar 61 And Altivar 61 Plus Variable Speed Drives Page 75 M-Flex

75 Altivar 61 variable speed drives Selection table M-Flex HP Refer- ence Code HP Ratings Control- ler Output Current Enclo- sure Frame Size Power Circuits Variable Torque - Normal Duty Rating (110% current Limit) Power Circuit W Power Circuit Y Power Circuit S Power Circuit Z Power Circuit T Power Circuit R 208V, 60 Hz C 1 4.6 A C C p 2VW C p 2VY - C p 2VZ C p 2VT - D 2 7.5 A D p 2VW D p 2VY - D p 2VZ D p 2VT - E 3 10.6 A E p 2VW E p 2VY - E p 2VZ E p 2VT - F 5 16.7 A F p 2VW F p 2VY - F p 2VZ F p 2VT - G 7.5 24.2 A D G p 2VW G p 2VY - G p 2VZ G p 2VT - H 10 30.8 A H p 2VW H p 2VY - H p 2VZ H p 2VT - J 15 46.2 A E J p 2VW J p 2VY - J p 2VZ J p 2VT - K 20 59.4 A K p 2VW K p 2VY - K p 2VZ K p 2VT - L 25 74.8 A L p 2VW L p 2VY - L p 2VZ L p 2VT - M 30 88 A F M p 2VW M p 2VY - M p 2VZ M p 2VT - N 40 114 A N p 2VW N p 2VY - N p 2VZ N p 2VT - P 50 130 A P p 2VW P p 2VY - P p 2VZ P p 2VT - 230 V, 60 Hz C 1 4.2 A C C p 3VW C p 3VY - C p 3VZ C p 3VT - D 2 6.8 A D p 3VW D p 3VY - D p 3VZ D p 3VT - E 3 9.6 A E p 3VW E p 3VY - E p 3VZ E p 3VT - F 5 15.2 A F p 3VW F p 3VY - F p 3VZ F p 3VT - G 7.5 22 A D G p 3VW G p 3VY - G p 3VZ G p 3VT - H 10 28 A H p 3VW H p 3VY - H p 3VZ H p 3VT - J 15 42 A E J p 3VW J p 3VY - J p 3VZ J p 3VT - K 20 54 A K p 3VW K p 3VY - K p 3VZ K p 3VT - L 25 68 A L p 3VW L p 3VY - L p 3VZ L p 3VT - M 30 80 A F M p 3VW M p 3VY - M p 3VZ M p 3VT - N 40 104 A N p 3VW N p 3VY - N p 3VZ N p 3VT - P 50 130 A P p 3VW P p 3VY - P p 3VZ P p 3VT - 460 V, 60 Hz C 1 2.1 A C C p 4VW C p 4VY - C p 4VZ C p 4VT - D 2 3.4 A D p 4VW D p 4VY - D p 4VZ D p 4VT - E 3 4.8 A E p 4VW E p 4VY - E p 4VZ E p 4VT - F 5 7.6 A F p 4VW F p 4VY - F p 4VZ F p 4VT - G 7.5 11 A G p 4VW G p 4VY - G p 4VZ G p 4VT - H 10 14 A H p 4VW H p 4VY - H p 4VZ H p 4VT - J 15 21 A J p 4VW J p 4VY - J p 4VZ J p 4VT - K 20 27 A K p 4VW K p 4VY - K p 4VZ K p 4VT - L 25 34 A L p 4VW L p 4VY - L p 4VZ L p 4VT - M 30 40 A E M p 4VW M p 4VY - M p 4VZ M p 4VT - N 40 52 A N p 4VW N p 4VY N p 4VS N p 4VZ N p 4VT N p 4VR P 50 65 A P p 4VW P p 4VY P p 4VS P p 4VZ P p 4VT P p 4VR Q 60 77 A F Q p 4VW Q p 4VY Q p 4VS Q p 4VZ Q p 4VT Q p 4VR R 75 96 A R p 4VW R p 4VY R p 4VS R p 4VZ R p 4VT R p 4VR S 100 124 A S p 4VW S p 4VY S p 4VS S p 4VZ S p 4VT S p 4VR T 125 156 A H T p 4VW T p 4VY T p 4VS T p 4VZ T p 4VT T p 4VR U 150 180 A I U p 4VW U p 4VY U p 4VS U p 4VZ U p 4VT U p 4VR W 200 240 A W p 4VW W p 4VY W p 4VS W p 4VZ W p 4VT W p 4VR X 250 302 A X p 4VW - X p 4VS X p 4VZ X p 4VT X p 4VR Y 300 361 A J Y p 4VW - Y p 4VS Y p 4VZ Y p 4VT Y p 4VR Z 350 414 A Z p 4VW - Z p 4VS Z p 4VZ Z p 4VT Z p 4VR 4 400 477 A 4 p 4VW - 4 p 4VS 4 p 4VZ 4 p 4VT 4 p 4VR 5 450 515 A 5 p 4VW - 5 p 4VS 5 p 4VZ 5 p 4VT 5 p 4VR 6 500 590 A 6 p 4VW 6 p 4VS 6 p 4VZ 6 p 4VT 6 p 4VR Class Combination device 8839 = Circuit breaker disconnect Type Design MFD = M-Flex controller Horsepower rating C = 1 L = 25 U = 150 D = 2 M = 30 W = 200 E = 3 N = 40 X = 250 F = 5 P = 50 Y = 300 G = 7.5 Q = 60 Z = 350 H = 10 R = 75 4 = 400 J = 15 S = 100 5 = 450 K = 20 T = 125 6 = 500 Enclosure environmental rating G = Type 1 general purpose A = Type 12/12K dust/drip proof B = Type 1 with gasket/fan filter Replace p with desired enclosure rating Voltage code 2 = 208 V, 60 Hz 3 = 230 V/240 V, 60 Hz 4 = 460 V/480 V, 60 Hz Application type V = Variable torque (110% current limit) Power circuit type R = Barriered bypass - RVAT S = Barriered bypass - soft start T = Isolation & transfer W = Combination device (drive only) Y = Integrated bypass (IEC) Z = Barriered bypass - full voltage Mods Modifications (120+ options are available) A07 = Hand-Off-Auto selector switch with manual speed potentiometer H10 = Seismic qualified E301 = ANSI #61 enclosure paint SPL = Special features (specified) Series Series designation A = Altivar 61 power converter platform 1 2 3 4 5 6 7 8 9 8839 MFD N G 4 V W A07 A 1 2 3 4 5 6 7 8 9

Previous Page
Next Page