Altivar 71 And Altivar 71 Plus Variable Speed Drives Page 19 Selection Tables

19 Altivar 71 variable speed drives IP 20 drives, 200...240 V 50/60 Hz Selection Table ATV71 H Product Family Altivar 71 product family Variation of Platform Standard product on heatsink Power Range (kW) 0 pp = 0.01 x pp (075 = 0.01 x 75 = 0.75 kW) U pp = 0.1 x pp (U75 = 0.1 x 75 = 7.5 kW) D pp = 1 x pp (D75 = 1 x 75 = 75 kW) C pp = 10 x pp (C75 = 10 x 75 = 750 kW) Supply Voltage M3 = 200-240V 1P or 3P N4 = 380-480V 3P S6 = 500-600V 3P Y = 500-690V 3P Part number explanation 0 pp U pp D pp C pp N4 M3 S6 Y X - EMC Filter Nothing = Class A EMC filter integrated X = Without EMC filter ATV71H075M3 ATV71HU55M3 ATV71HD30M3X Single phase input Motor Line supply Altivar 71 Power (1) Line current (2) Max. prospective line Isc Maximum continuous current (1) Max. transient current for Part Number (3) Frame Size Weight 200 V 240 V 230 V 60 s 2 s g k s b l A A k A W k P H Single-phase supply voltage, without line reactor: 200240 V 50/60 Hz 0.5 .37 6.9 5.8 5 3 4.5 4.9 ATV71H075M3 2 6.6 3 1 .75 12 9.9 5 4.8 7.2 7.9 ATV71HU15M3 2 6.6 3 2 1.5 18.2 15.7 5 8 12 13.2 ATV71HU22M3 3 8.8 4 3 2.2 25.9 22.1 5 11 16.5 18.1 ATV71HU30M3 3 8.8 4 5 4 47.3 40.1 5 1 26.3 29.7 ATV71HU75M3 5A 15.4 7 7.5 6 - 51.4 5 27.5 41.3 45.3 ATV71HD15M3X (4) 5B 19.8 9 10 8 - 59.6 5 33 49.5 54.5 ATV71HD18M3X (4) 6 66.1 30 15 11 - 88.4 5 54 81 89.1 ATV71HD30M3X (4) 7B 81.6 37 20 15 - 111.1 5 66 99 109 ATV71HD37M3X (4) 7B 81.6 37 25 18 - 137.6 10 75 112 124 ATV71HD45M3X (4) 7B 81.6 37 Single-phase supply voltage, with 5% line reactor: 200...240 V 50/60 Hz - 3 25.9 22 5 13.6 20.6 22.6 ATV71HU40M3 3 8.8 4 5 4 34.9 29.9 5 17.5 26.3 28.8 ATV71HU55M3 4 12.1 5.5 7.5 6 47.3 40.1 22 27.5 41.3 45.3 ATV71HU75M3 5A 15.3 7 10 8 - 54 22 33 49.5 54.5 ATV71HD15M3X (4) 5B 19.8 9 15 11 - 78.3 22 54 81 89.1 ATV71HD22M3X (4) 6 66.1 30 20 15 - 101.5 22 66 99 109 ATV71HD30M3X (4) 7B 81.6 37 25 18 - 131 22 75 112 124 ATV71HD37M3X (4) 7B 81.6 37 30 22 - 145.9 22 88 132 145 ATV71HD45M3X (4) 7B 81.6 37 Dimensions (overall) D x H x W e z i S e m a r F m m s e h c n i 2 5 7 1 x 0 3 2 x 0 3 1 9 . 6 x 1 . 9 x 1 . 5 3 7 8 1 x 0 6 2 x 5 5 1 4 . 7 x 2 . 0 1 x 1 . 6 4 7 8 1 x 5 9 2 x 5 7 1 4 . 7 x 6 . 1 1 x 9 . 6 5A 3 1 2 x 5 9 2 x 0 1 2 4 . 8 x 6 . 1 1 x 3 . 8 5B 3 1 2 x 0 0 4 x 0 3 2 4 . 8 x 7 . 5 1 x 1 . 9 6 6 3 2 x 0 2 4 x 0 4 2 3 . 9 x 5 . 6 1 x 4 . 9 7B 6 6 2 x 0 5 5 x 0 2 3 5 . 0 1 x 6 . 1 2 x 6 . 2 1 (1) These values are given for a nominal switching frequency of 4 kHz up to ATV71HD15M3X or 2.5 kHz for ATV71HD18M3XHD75M3X drives for use in continuous operation. The switching frequency is adjustable from 116 kHz up to ATV71HD45M3X and from 18 kHz for ATV71HD55M3X and ATV71HD75M3X drives. Above 2.5 or 4 kHz, depending on the rating, the drive will reduce the switching frequency automatically in the event of an excessive temperature rise. For continuous operation above the nominal switching frequency, derate the nominal drive current.. (2) Typical value for the indicated motor power and for the maximum prospective line Isc. (3) Variants available. (4) Note: Part numbers ending with ...M3X do not include an integrated EMC filter. EMC filters are available as an option.

Previous Page
Next Page