Altivar 71 And Altivar 71 Plus Variable Speed Drives Page 64 Input Power Options

64 Altivar 71 variable speed drives EMC filters Input Power Options Additional EMC input filters (for ATV71H ppp M3, H ppp M3 and ATV71 pppp N4 drives) Drives Maximum length of shielded cable (1) In (2) If (3) Loss (4) Part number Weight EN 55011 class A Gr1 EN 55011 class B Gr1 IEC/EN 61800-3 category C2 IEC/EN 61800-3 category C1 LF HF LF HF ft m ft m ft m ft m A mA W lbs kg Three-phase supply voltage: 200240 V 50/60 Hz ATV71H037M3HU15M3 328.1 100 164 50 164 50 65.6 20 12 4 10 VW3A4401 4.9 2.2 ATV71HU22M3HU40M3 328.1 100 164 50 164 50 65.6 20 26 4.4 18 VW3A4402 8.8 4 ATV71HU55M3 328.1 100 164 50 164 50 65.6 20 35 3 24 VW3A4403 12.7 5.8 ATV71HU75M3 328.1 100 164 50 164 50 65.6 20 46 10 19 VW3A4404 15.4 7 ATV71HD11M3X, HD15M3X 328.1 100 164 50 164 50 82 25 72 33 34 VW3A4405 26.5 12 ATV71HD18M3X, HD22M3X 328.1 100 164 50 164 50 82 25 90 33 34 VW3A4406 33.1 15 ATV71HD30M3X... HD45M3X 328.1 100 164 50 164 50 82 25 180 80 58 VW3A4408 88.2 40 ATV71HD55M3X, HD75M3X 328.1 100 164 50 164 50 82 25 273 285 60 VW3A4410 55.1 25 Three-phase supply voltage: 380480 V 50/60 Hz ATV71H075N4HU22N4 328.1 100 164 50 164 50 65.6 20 12 7 5 VW3A4401 4.9 2.2 ATV71HU30N4, HU40N4 328.1 100 164 50 164 50 65.6 20 26 8 6 VW3A4402 8.8 4 ATV71HU55N4, HU75N4 328.1 100 164 50 164 50 65.6 20 35 7 14 VW3A4403 12.7 5.8 ATV71HD11N4 328.1 100 164 50 164 50 65.6 20 46 14 13 VW3A4404 15.4 7 ATV71HD15N4 (5) , HD18N4 984.3 300 656.2 200 328.1 100 328.1 100 72 60 14 VW3A4405 26.5 12 ATV71HD22N4 984.3 300 656.2 200 328.1 100 328.1 100 90 60 11 VW3A4406 33.1 15 ATV71HD30N4, HD37N4 984.3 300 656.2 200 328.1 100 328.1 100 92 60 30 VW3A4407 37.5 17 ATV71HD45N4HD75N4 984.3 300 656.2 200 328.1 100 328.1 100 180 140 58 VW3A4408 88.2 40 ATV71HD90N4HC13N4 984.3 300 492.1 150 164 50 82 25 273 500 60 VW3A4410 48.5 22 ATV71HC16N4HC28N4 984.3 300 492.1 150 164 50 82 25 546 500 125 VW3A4411 55.1 25 ATV71HC31...HC40N4 984.3 300 492.1 150 164 50 82 25 728 500 210 VW3A4412 55.1 25 ATV71HC50N4 984.3 300 492.1 150 164 50 82 25 1456 200 380 VW3A4413 75 34 For drives Switching frequency LF (low frequency) HF (high frequency) kHz ATV71H ppp M3 ATV71H075N4HD11N4 4 4.116 ATV71HD11M3X, HD15M3X ATV71HD15N4HD30N4 3.5...4 4.112 ATV71HD18M3X...HD45M3X ATV71HD37N4...HD75N4 22.5 2.612 ATV71HD55M3X, HD75M3X 24 4.18 ATV71HD90N4...HC50N4 24 4.18 (1) These limits are given as examples only as they vary depending on the stray capacitance of the motors and the cables used. If motors are connected in parallel, it is the sum of all cable lengths that should be taken into account. (2) Nominal filter current. (3) Maximum ground leakage current at 230 V and at 400 V 50 Hz on a TT system. (4) Via heat dissipation. (5) It is possible to use a special filter VW3A4409 with a leakage current If (3) of 14 mA which enables a maximum motor cable length of 100 m.

Previous Page
Next Page