Altivar 71 And Altivar 71 Plus Variable Speed Drives Page 69 M-Flex

69 Altivar 71 variable speed drives Selection table M-Flex HP Refer- ence Code HP Ratings Control- ler Output Current Enclo- sure Frame Size Power Circuits Constant Torque - Heavy Duty Rating (150% current Limit) Power Circuit W Power Circuit Y Power Circuit S Power Circuit Z Power Circuit T Power Circuit R 208V, 60 Hz C 1 4.6 A C C p 2CW C p 2CY - C p 2CZ C p 2CT - D 2 7.5 A D p 2CW D p 2CY - D p 2CZ D p 2CT - E 3 10.6 A E p 2CW E p 2CY - E p 2CZ E p 2CT - F 5 16.7 A F p 2CW F p 2CY - F p 2CZ F p 2CT - G 7.5 24.2 A D G p 2CW G p 2CY - G p 2CZ G p 2CT - H 10 30.8 A H p 2CW H p 2CY - H p 2CZ H p 2CT - J 15 46.2 A E J p 2CW J p 2CY - J p 2CZ J p 2CT - K 20 59.4 A K p 2CW K p 2CY - K p 2CZ K p 2CT - L 25 74.8 A L p 2CW L p 2CY - L p 2CZ L p 2CT - M 30 88 A F M p 2CW M p 2CY - M p 2CZ M p 2CT - N 40 114 A N p 2CW N p 2CY - N p 2CZ N p 2CT - 230 V, 60 Hz C 1 4.6 A C C p 3CW C p 3CY - C p 3CZ C p 3CT - D 2 7.5 A D p 3CW D p 3CY - D p 3CZ D p 3CT - E 3 10.6 A E p 3CW E p 3CY - E p 3CZ E p 3CT - F 5 16.7 A F p 3CW F p 3CY - F p 3CZ F p 3CT - G 7.5 24.2 A D G p 3CW G p 3CY - G p 3CZ G p 3CT - H 10 30.8 A H p 3CW H p 3CY - H p 3CZ H p 3CT - J 15 46.2 A E J p 3CW J p 3CY - J p 3CZ J p 3CT - K 20 59.4 A K p 3CW K p 3CY - K p 3CZ K p 3CT - L 25 74.8 A L p 3CW L p 3CY - L p 3CZ L p 3CT - M 30 88 A F M p 3CW M p 3CY - M p 3CZ M p 3CT - N 40 114 A N p 3CW N p 3CY - N p 3CZ N p 3CT - 460 V, 60 Hz C 1 2.1 A C C p 4CW C p 4CY - C p 4CZ C p 4CT - D 2 3.4 A D p 4CW D p 4CY - D p 4CZ D p 4CT - E 3 4.8 A E p 4CW E p 4CY - E p 4CZ E p 4CT - F 5 7.6 A F p 4CW F p 4CY - F p 4CZ F p 4CT - G 7.5 11 A G p 4CW G p 4CY - G p 4CZ G p 4CT - H 10 14 A H p 4CW H p 4CY - H p 4CZ H p 4CT - J 15 21 A J p 4CW J p 4CY - J p 4CZ J p 4CT - K 20 27 A K p 4CW K p 4CY - K p 4CZ K p 4CT - L 25 34 A L p 4CW L p 4CY - L p 4CZ L p 4CT - M 30 40 A E M p 4CW M p 4CY - M p 4CZ M p 4CT - N 40 52 A N p 4CW N p 4CY N p 4CS N p 4CZ N p 4CT N p 4CR P 50 65 A P p 4CW P p 4CY P p 4CS P p 4CZ P p 4CT P p 4CR Q 60 77 A F Q p 4CW Q p 4CY Q p 4CS Q p 4CZ Q p 4CT Q p 4CR R 75 96 A R p 4CW R p 4CY R p 4CS R p 4CZ R p 4CT R p 4CR S 100 124 A S p 4CW S p 4CY S p 4CS S p 4CZ S p 4CT S p 4CR T 125 156 A H T p 4CW T p 4CY T p 4CS T p 4CZ T p 4CT T p 4CR U 150 180 A I U p 4CW U p 4CY U p 4CS U p 4CZ U p 4CT U p 4CR W 200 240 A W p 4CW W p 4CY W p 4CS W p 4CZ W p 4CT W p 4CR X 250 302 A X p 4CW - X p 4CS X p 4CZ X p 4CT X p 4CR Y 300 361 A J Y p 4CW - Y p 4CS Y p 4CZ Y p 4CT Y p 4CR Z 350 414 A Z p 4CW - Z p 4CS Z p 4CZ Z p 4CT Z p 4CR 4 400 477 A 4 p 4CW - 4 p 4CS 4 p 4CZ 4 p 4CT 4 p 4CR 5 450 515 A 5 p 4CW - 5 p 4CS 5 p 4CZ 5 p 4CT 5 p 4CR Class Combination device 8839 = Circuit breaker disconnect Type Design MFD = M-Flex controller Horsepower rating C = 1 L = 25 U = 150 D = 2 M = 30 W = 200 E = 3 N = 40 X = 250 F = 5 P = 50 Y = 300 G = 7.5 Q = 60 Z = 350 H = 10 R = 75 4 = 400 J = 15 S = 100 5 = 450 K = 20 T = 125 6 = 500 Enclosure environmental rating G = Type 1 general purpose A = Type 12/12K dust/drip proof B = Type 1 with gasket/fan filter Replace p with desired enclosure rating Voltage code 2 = 208 V, 60 Hz 3 = 230 V/240 V, 60 Hz 4 = 460 V/480 V, 60 Hz Application type C = Constant torque (150% current limit) Power circuit type R = Barriered bypass - RVAT S = Barriered bypass - soft start T = Isolation & transfer W = Combination device (drive only) Y = Integrated bypass (IEC) Z = Barriered bypass - full voltage Mods Modifications (120+ options are available) A07 = Hand-Off-Auto selector switch with manual speed potentiometer H10 = Seismic qualified E301 = ANSI #61 enclosure paint SPL = Special features (specified) Series Series designation A = Altivar 61/71 power converter platform 1 2 3 4 5 6 7 8 9 8839 MFD N G 4 V W A07 A 1 2 3 4 5 6 7 8 9

Previous Page
Next Page