Altivar 71 And Altivar 71 Plus Variable Speed Drives Page 71 M-Flex

71 Altivar 71 variable speed drives Dimensions M-Flex M-Flex Enclosed AC Drives Class 8839 Type MFD with or without options Dimensions Weights Construction Data HP/Voltage (CT) Power Circuit Configuration Enclosure Size Height (in) Width (in) Depth (in) lbs. Wall or Floor Mount Environ- ment Operating Handle 1 hp to 20 hp @ 460 V 1 hp to 5 hp @ 208 V/230 V Power circuit W combination device or power circuit Y integrated bypass C 49 20 14.81 175 Wall Type 1 or Type 12/12K 3" metal rotary 7.5 hp to 10 hp @ 208 V/230 V D 63 25 14.81 243 Wall 25 hp to 40 hp @ 460 V 15 hp to 20 hp @ 208 V/230 V E 93.87 20 20.38 170.5 Floor 6" metal rotary 50 hp to 75 hp @ 460 V 25 hp to 40 hp @ 208 V/230 V F 93.87 25 20.38 249.1 Floor 1 hp to 20 hp @ 460 V 1 hp to 10 hp @ 208 V/230 V Power circuits Z, S, T or R barriered designs with 2 disconnects Barriered C/D 93.87 20 20.38 379 Floor 3" metal rotary 25 hp to 40 hp @ 460 V 15 hp to 20 hp @ 208 V/230 V Barriered E 93.87 25 20.38 512 Floor 6" metal rotary 50 hp to 75 hp @ 460 V 25 hp to 40 hp @ 208 V/230 V Barriered F 93.87 30 20.38 684 Floor 100 hp @ 460 V Power circuit W (1) H 94.58 25 20 489 Floor Type 1 or Type 1A filtered Flange 125 hp to 200 hp @ 460 V Power circuit W (2,3) I 94.58 30 20 657 Floor 250 hp to 450 hp @ 460 V Power circuit W (4,5) J 94.58 35 20 969 Floor (1) Integrated bypass for 125 hp offered in 20 in. wide section adder (45 in. total width). Barriered bypass offered in 25 in. wide section adder (50 in. total width) - standard product configuration (2) Integrated bypass for 150 hp to 200 hp offered in 20 in. wide section adder (50 in. total width). Barriered bypass offered in 25 in. wide section adder (55 in. total width) - standard configuration (3) Integrated bypass for 250 hp offered in 20 in. wide section adder (50 in. total width). Barriered bypass offered in 30 in. wide section adder (60 in. total width) - factory engineered configuration (4) Integrated bypass for 300 hp to 400 hp not available. Barriered bypass offered in 30 in. wide section adder (65 in. total width) - factory engineered configuration (5) Integrated bypass for 450 hp to 500 hp not available. Barriered bypass offered in 35 in. wide section adder (70 in. total width) - factory engineered configuration Power Circuit - Description R - Barriered bypass with autotransformer reduced voltage starter S - Barriered bypass with soft start T - Isolation and transfer (separate starter) W - Combination drive with disconnect means only Y - Integrated-bypass drive with full-voltage starter in same enclosure compartment Z - Barriered-bypass drive with full-voltage starter in separate enclosure compartment

Previous Page
Next Page