Home / altivar-process-600-variable-speed-drives / Page 37

Altivar Process 600 Variable Speed Drives - Page 37 Accessories and Options

37

Altivar Process 600 variable speed drives

Accessories & Options Communication Card Options

CANopen machine bus

(4) Description Item no. Length Part number Weight ft m lbs kg

Communication card

CANopen daisy chain card Ports: 2 RJ45 connectors 1 - - VW3A3608 - -

Connection to RJ45 connector (optimized solution for daisy chain connection on CANopen bus)

CANopen cordsets equipped with 2 RJ45 connectors 2 0.98 0.3 VW3CANCARR03 0.11 0.05 3.28 1 VW3CANCARR1 1.10 0.50 CANopen line terminator for RJ45 connector 3 - - TCSCAR013M120 - -

Communication card

CANopen SUB-D card Ports: 1 x 9-way male SUB-D connector 4 - - VW3A3618 - -

Connection to SUB-D connector

CANopen cables

(3) (4)

Standard cable, e mark Low smoke zero halogen Flame-retardant (IEC 60332-1) 5 164.04 50 TSXCANCA50 10.87 4.93 328.08 100 TSXCANCA100 19.40 8.80 984.25 300 TSXCANCA300 54.15 24.56 CANopen cables

(3) (4)

UL certification, e mark Flame-retardant (IEC 60332-2) 5 164.04 50 TSXCANCB50 7.89 3.58 328.08 100 TSXCANCB100 17.28 7.84 984.25 300 TSXCANCB300 48.22 21.87 CANopen cables

(3) (4)

Cable for harsh environments or mobile installments, e mark Low stroke zero halogen

Flame retardant (IEC 60332-1)

5 164.04 50 TSXCANCD50 7.74 3.51 328.08 100 TSXCANCD100 17.13 7.77 984.25 300 TSXCANCD300 17.13 7.77 IP 20 straight CANopen connector

(5)

9-way female SUB-D connector with line terminator that can be deactivated. For connecting CAN-H, CAN-L, and CAN-GND 6 - - TSXCANKCDF180T 0.11 0.05

(1) Altivar Process drives can only take one communication card. (2) Please refer to the "Modicon

TM

automation platform" catalogs on our website www.schneider-electric.com. (3) Cable depends on the PLC. (4) Standard environment: - no particular environmental constraints - operating temperature between +5 and +60 C/+41 and +140 F - fixed installation Harsh environment: - resistance to hydrocarbons, industrial oils, detergents, solder splashes - relative humidity up to 100% - saline atmosphere - operating temperature between -10 and +70 C/+14 and +158 F - significant temperature variations (5) Only straight connectors are compatible with Altivar Process drives.

VW3A3608

PF514340

VW3A3618

PF514341

Optimized solution for daisy chain connection to the CANopen bus PLC (2) Altivar Process drive + VW3A3608 card CANopen bus (3)

2 1 3

Example of connection to the CANopen bus via SUB-D connector PLC (2) Altivar Process drive + VW3A3618 card CANopen bus (3)

5 6 4

Previous Page