Altivar Process 900 Variable Speed Drives Page 4 IP 20, IP 21, IP 54 or IP 55 variable speed drive selection guide

4 Selection guide IP 20, IP 21, IP 54, or IP 55 variable speed drives for asynchronous and synchronous motors Market segments b Oil & gas b Mining, minerals & metals b Food & beverage b Water & wastewater Mounting type Wall-mounting Floor-standing Degree of protection IP 20 and IP 21/UL Type 1 IP 21/UL Type 1 without braking unit IP 21 without braking unit Power range for 50...60 Hz line supply (1) Three-phase: 200...240 V (kW/ HP ) 0.75 ...45/ 1...60 55...75/ 75...100 Three-phase: 380...440 V (kW) 110...315 Three-phase: 380...480 V (kW/ HP ) 0.75..220/ 1...350 55...315/ 75...500 Three-phase 500...690 V (kW/ HP ) 2.2...90/ 3...125 Drive Output frequency 0.1...599 Hz Control type Asynchronous motor Standard constant torque, optimized torque mode Synchronous motor PM (Permanent Magnet) motor Functions Advanced functions b Performance on motor control with an overload torque up to 180% Tn in an open or closed loop b Asynchronous,synchronous,specialmotors:alliciencyclasses,brandindependent, permanent magnet motors, torque motors, conical sliding rotor, reluctance motor b Integrated EtherNet/IP and Modbus TCP dual port, cybersecurity (Achilles Level 2) b Smart integration in PlantStruxure and Foxboro Evo process automation systems b Optimizedenergyiciency,detectionofenergyconsumptiondriftoftheinstallation b Adaptation to the process by dedicated functions with modular design b Embedded safety functions STO SIL3 b Master/slave and load sharing with drive-to-drive capability: v torque sharing on rigid coupling v torque sharing on elastic coupling b Contextual access to technical documentation through dynamic QR code b Continuous and historical real-time measurements with customizable dashboards b Predictive maintenance (e.g.: temperatures with PT100/1000 probe, fan monitoring, etc.) Integrated safety function 1: STO (Safe Torque Off) SIL3 Number of preset speeds 16 Number of integrated I/O Analog inputs 3: Configurable as voltage (0...10 V) or current (0-20 mA/4-20 mA), including 2 for probes (PTC, PT100, PT1000, or KTY84) Digital inputs 8: Voltage 24 V c (positive or negative logic) Digital output 1: Assignable Analog outputs 2: Configurable as voltage (0...10 V) or current (0-20 mA) Relay outputs 3: 1 with NO/NC contacts and 2 with NO contacts Safety function inputs 2: For safety function STO I/O extension modules (optional) Analog inputs 2 differential analog inputs configurable via software as current (0-20 mA/ 4-20 mA), or for PTC, PT100 or PT1000, 2 or 3-wire Digital inputs 6: Voltage 24 V c (positive or negative logic) Digital outputs 2: Assignable Relay output module (optional) Relay outputs 3: NO contacts Communication Integrated EtherNet/IP and Modbus/TCP dual port, Modbus serial link Option modules PROFINET, CANopen RJ45 Daisy Chain, Sub-D, and screw terminals, Profibus DP V1, EtherCAT, and DeviceNet Configuration and runtime tools Graphic display terminal, embedded web server, DTM (Device Type Manager), SoMove software Standards and certifications UL 508C, EN/IEC 61800-3, EN/IEC 61800-3 environment 1 category C2, EN/IEC 61800-3 environment 2 category C3, EN/IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, REACH EN/IEC 61800-3, EN/IEC 61800-3 environment 2 category C3, EN/IEC 61800-5-1, IEC 60721-3, IEC 61508 References ATV930 ppppp ATV930 ppppp C ATV930 ppppp F Page 18 24 (1) In Normal duty power values are given for applications requiring a slight overload (up to 120%). For power values in Heavy duty applications requiring a significant overload (up to 150%), see page 18. 4

Previous Page
Next Page