VW3A3608

PF514340

VW3A3618

PF514341

References

(continued)

Variable speed drives

Altivar Process ATV900

Communication buses and networks Option: Communication modules

Presentation: page 8 Variable speed drives: page 18 Configuration and runtime tools: page 28 Combinations: page 32 Dimensions: page 76

CANopen bus

(1) Description Item Length m/ ft Unit reference Weight kg/ lb

Fieldbus module

CANopen Daisy chain module Ports: 2 RJ45 connectors 1 VW3A3608

Connection to RJ45 connector (optimized solution for daisy chain connection on CANopen bus)

CANopen cordsets equipped with 2 RJ45 connectors 2 0.3/ 0.98 VW3CANCARR03 0.050/ 0.110 1/ 3.28 VW3CANCARR1 0.500/ 1.102 CANopen line terminator for RJ45 connector 3 TCSCAR013M120

Fieldbus module

CANopen SUB-D module Ports: 1 x 9-way male SUB-D connector 4 VW3A3618

Connection to SUB-D connector

CANopen cables (3) (4) Standard cable, e mark Low smoke zero halogen. Flame-retardant (IEC 60332-1) 5 50/ 164.04 TSXCANCA50 4.930/ 10.869 100/ 328.08 TSXCANCA100 8.800/ 19.401 300/ 984.25 TSXCANCA300 24.560/ 54.145 CANopen cables (3) (4) UL certification, e mark Flame-retardant (IEC 60332-2) 5 50/ 164.04 TSXCANCB50 3.580/ 7.893 100/ 328.08 TSXCANCB100 7.840/ 17.284 300/ 984.25 TSXCANCB300 21.870/ 48.215 CANopen cables (3) (4) Cable for harsh environments or mobile installations, e mark Low smoke zero halogen Flame-retardant (IEC 60332-1) 5 50/ 164.04 TSXCANCD50 3.510/ 7.738 100/ 328.08 TSXCANCD100 7.770/ 17.130 300/ 984.25 TSXCANCD300 7.770/ 17.130 IP 20 straight CANopen connector (5) 9-way female SUB-D connector with line terminator that can be deactivated For connecting CAN-H, CAN-L, CAN-GND 6 TSXCANKCDF180T 0.049/ 0.108 (1) Altivar Process drives can only take one fieldbus module. (2) Please refer to the Modicon automation platform catalogs on our website www.schneider-electric.com. (3) Cable depends on the PLC. (4) Standard environment: - No particular environmental constraints - Operating temperature between +5 C and +60 C/+41 F and +140 F - Fixed installation Harsh environment: - Resistance to hydrocarbons, industrial oils, detergents, solder splashes - Relative humidity up to 100% - Saline atmosphere - Operating temperature between -10 C and +70 C/+14 F and 158 F - Significant temperature variations (5) Only straight connectors are compatible with Altivar Process drives. Optimized solution for daisy chain connection to the CANopen bus Altivar Process + VW3A3608 module Controller (1) CANopen bus (3)

2 1 3 5 6 4

Example of connection to the CANopen bus via SUB-D connector Altivar Process + VW3A3618 module CANopen bus (3) Controller (1)