Altivar Process 900 Variable Speed Drives Page 70 Motor starters

70 Combinations for customer assembly Variable speed drives Altivar Process ATV900 Motor starters Supply voltage 200...240 V Applications Circuit breaker/contactor/drive combinations help to ensure continuity of service in the installation. The type of circuit breaker/contactor coordination selected can reduce maintenance costs in the event of a short-circuit on the drive input by minimizing the time required to make the necessary repairs and the cost of replacement equipment. The suggested combinations provide coordination according to the drive rating. The drive controls the motor, provides a monitoring function against short-circuits between the drive and the motor, and helps protect the motor cable against overloads. Overload monitoring is provided by the drive's motor thermal monitoring function if this has been enabled. Otherwise, an external monitoring device such as a probe or thermal overload relay should be provided. The circuit breaker helps protect the drive's power cables against short-circuits. IEC standard motor starters Motor Drive Circuit breaker Line contactor Power (1) Reference Reference (2) Rating Irm Reference (3) (4) kW HP A Three-phase supply voltage: 200240 V 50/60 Hz 0.75 1 ATV930U07M3 GV2L08 4 51 LC1D09 pp 1.5 2 ATV930U15M3 GV2L10 6.3 78 LC1D09 pp 2.2 3 ATV930U22M3 GV2L14 10 138 LC1D09 pp 3 ATV930U30M3 GV2L16 14 170 LC1D18 pp 4 5 ATV930U40M3 GV2L20 18 223 LC1D18 pp 5.5 7.5 ATV930U55M3 GV2L22 25 327 LC1D25 pp 7.5 10 ATV930U75M3 GV2L32 32 448 LC1D40A pp 11 15 ATV930D11M3 GV3L40 40 560 LC1D40A pp 15 20 ATV930D15M3 GV3L65 65 910 LC1D65A pp 18.5 25 ATV930D18M3 NS80HMA 80 1000 LC1D65A pp 22 30 ATV930D22M3 NS80HMA 80 1000 LC1D80 pp 30 40 ATV930D30M3 NSX100 p MA100 100 1300 LC1D95 pp 30 40 ATV930D30M3C NSX100 p MA100 100 1300 LC1D95 pp 37 50 ATV930D37M3 NSX160 p MA150 150 1500 LC1D115 pp 37 50 ATV930D37M3C NSX160 p MA150 150 1500 LC1D115 pp 45 60 ATV930D45M3 NSX160 p MA150 150 1500 LC1D150 pp 45 60 ATV930D45M3C NSX160 p MA150 150 1500 LC1D150 pp 55 75 ATV930D55M3C NSX250 p MA220 220 2420 LC1F185 pp 75 100 ATV930D75M3C NSX400 p Micrologic 1.3-M 320 3500 LC1F265 pp (1) Standard power ratings for 230 V 50/60 Hz 4-pole motors. The values expressed in HP conform to the NEC (National Electrical Code). (2) For references to be completed, replace the dot with the letter corresponding to the breaking performance of the circuit breaker (F, N, H, S or L). Breaking capacity of circuit breakers according to standard IEC 60947-2: Circuit breaker Icu (kA) for 200240 V F N H S L GV2L08L20 >100 GV2L22...L32 50 GV3L40L65 100 NS80HMA 100 NSX100 p MA100 85 90 100 120 150 NSX160 p MA150 85 90 100 120 150 NSX250 p MA220 85 90 100 120 150 NSX400 p Micrologic 1.3-M 40 85 100 120 150 (3) Composition of contactors: LC1D09...D150: 3 poles + 1 NO auxiliary contact + 1 NC auxiliary contact LC1F185...F265: 3 poles To add auxiliary contacts or other accessories, please refer to the Motor-starter solutions - Control and protection components catalog. (4) Replace pp with the control circuit voltage code indicated in the table below: Volts a 24 48 110 220 230 240 LC1D09D150 50 Hz B5 E5 F5 M5 P5 U5 60 Hz B6 E6 F6 M6 - U6 50/60 Hz B7 E7 F7 M7 P7 U7 LC1F185 50 Hz (LX1 coil) B5 E5 F5 M5 P5 U5 60 Hz (LX1 coil) E6 F6 M6 - U6 40...400 Hz (LX9 coil) E7 F7 M7 P7 U7 LC1F265 40...400 Hz (LX1 coil) B7 E7 F7 M7 P7 U7 For other voltages available between 24 V and 660 V, or a DC control circuit, please contact our Customer Care Center. GV3L40 PB108363 LC1D40A pp PB108335 ATV930D11M3 PF151202 Presentation: page 8 References: page 18 Configuration and runtime tools: page 28 Combinations: page 32 Dimensions: page 76

Previous Page
Next Page