Combinations for customer assembly

(continued)

Variable speed drives

Altivar Process ATV900

Motor starters Supply voltage 380...415 V

IEC standard motor starters

Motor Drive Circuit breaker Line contactor Power (1) Reference Reference (2) Rating Irm Reference (3) (4) kW HP A

Three-phase supply voltage: 380415 V 50/60 Hz

0.75 1 ATV930U07N4 GV2L07 2.5 33.5 LC1D09 pp 1.5 2 ATV930U15N4 GV2L08 4 51 LC1D09 pp 2.2 3 ATV930U22N4 GV2L10 6.3 78 LC1D09 pp 3 ATV930U30N4 GV2L14 10 138 LC1D09 pp 4 5 ATV930U40N4 GV2L14 10 138 LC1D09 pp 5.5 7.5 ATV930U55N4 GV2L16 14 170 LC1D18 pp 7.5 10 ATV930U75N4 GV2L20 18 223 LC1D18 pp 11 15 ATV930D11N4 GV2L22 25 327 LC1D25 pp 15 20 ATV930D15N4 GV3L32 32 448 LC1D25 pp 18.5 25 ATV930D18N4 GV3L40 40 560 LC1D40A pp 22 30 ATV930D22N4 GV3L50 50 700 LC1D50A pp 30 40 ATV930D30N4 GV3L65 65 910 LC1D50A pp 37 50 ATV930D37N4 NS80HMA 80 1000 LC1D65A pp 45 60 ATV930D45N4 NSX100 p MA100 100 1300 LC1D80 pp 55 75 ATV930D55N4 NSX160 p MA150 150 1500 LC1D115 pp 55 75 ATV930D55N4C NSX160 p MA150 150 1500 LC1D115 pp 75 100 ATV930D75N4 NSX160 p MA150 150 1500 LC1D115 pp 75 100 ATV930D75N4C NSX160 p MA150 150 1500 LC1D115 pp 90 125 ATV930D90N4 NSX250 p MA220 220 2420 LC1F185 pp 90 125 ATV930D90N4C NSX250 p MA220 220 2420 LC1F185 pp 110 150 ATV930C11N4C NSX250 p MA220 220 2860 LC1F185 pp 132 200 ATV930C13N4C NSX400 p Micrologic 1.3-M 320 3500 LC1F265 pp 160 250 ATV930C16N4C NSX400 p Micrologic 1.3-M 320 4000 LC1F265 pp 220 350 ATV930C22N4 NSX630 p Micrologic 1.3-M 500 3000 LC1F400 pp 220 350 ATV930C22N4C NSX630 p Micrologic 1.3-M 500 3000 LC1F400 pp 250 400 ATV930C25N4C NSX630 p Micrologic 1.3-M 500 3000 LC1F500 pp 315 500 ATV930C31N4C NS800L Micrologic 2 or 5 800 1600 LC1F630 pp (1) Standard power ratings for 400 V 50/60 Hz 4-pole motors. The values expressed in HP conform to the NEC (National Electrical Code). (2) For references to be completed, replace the dot with the letter corresponding to the breaking performance of the circuit breaker (F, N, H, S or L). Breaking capacity of circuit breakers according to standard IEC 60947-2: Circuit breaker Icu (kA) for 380415 V F N H S L GV2L07L14 100 GV2L16L22 50 GV3L32L65 50 NS80HMA 70 NSX100 p MA100 36 50 70 100 150 NSX160 p MA150 36 50 70 100 150 NSX250 p MA220 36 50 70 100 150 NSX400 p , NSX630 p 36 50 70 100 150 NS800L Micrologic 2 or 5 - 150 (3) Composition of contactors: LC1D09...D115: 3 poles + 1 NO auxiliary contact + 1 NC auxiliary contact LC1F185...F265: 3 poles To add auxiliary contacts or other accessories, please refer to the Motor-starter solutions - Control and protection components catalog. (4) Replace pp with the control circuit voltage code indicated in the table below: Volts a 24 48 110 220 230 240 LC1D09...D115 50 Hz B5 E5 F5 M5 P5 U5 60 Hz B6 E6 F6 M6 - U6 50/60 Hz B7 E7 F7 M7 P7 U7 LC1F185 50 Hz (LX1 coil) B5 E5 F5 M5 P5 U5 60 Hz (LX1 coil) E6 F6 M6 - U6 40...400 Hz (LX9 coil) E7 F7 M7 P7 U7 LC1F265 40...400 Hz (LX1 coil) B7 E7 F7 M7 P7 U7 LC1F400...F800 40...400 Hz (LX1 coil) E7 F7 M7 P7 U7 For other voltages available between 24 V and 660 V, or a DC control circuit, please contact our Customer Care Center. Presentation: page 8 References: page 18 Configuration and runtime tools: page 28 Combinations: page 32 Dimensions: page 76 NSX100FMA100

PB103194

LC1D80 pp

PB108308

ATV930D45N4

PF151203

Previous Page
Next Page