Altivar Process 900 Variable Speed Drives Page 74 Motor starters

74 Combinations for customer assembly (continued) Variable speed drives Altivar Process ATV900 Motor starters Supply voltage 440 V IEC standard motor starters Motor Drive Circuit breaker Line contactor Power (1) Reference Reference (2) Rating Irm Reference (3) (4) (5) kW HP A Three-phase supply voltage: 440 V 50/60 Hz 0.75 1 ATV950U07N4/N4E GV2L07 2.5 33.5 LC1D09 pp 1.5 2 ATV950U15N4/N4E GV2L08 4 51 LC1D09 pp 2.2 3 ATV950U22N4/N4E GV2L10 6.3 78 LC1D09 pp 3 ATV950U30N4/N4E GV2L10 6.3 78 LC1D09 pp 4 5 ATV950U40N4/N4E GV2L14 10 138 LC1D09 pp 5.5 7.5 ATV950U55N4/N4E GV2L16 14 170 LC1D18 pp 7.5 10 ATV950U75N4/N4E GV2L16 14 170 LC1D18 pp 11 15 ATV950D11N4/N4E GV2L22 25 327 LC1D25 pp 15 20 ATV950D15N4/N4E GV3L32 32 448 LC1D25 pp 18.5 25 ATV950D18N4/N4E GV3L40 40 560 LC1D40A pp 22 30 ATV950D22N4/N4E GV3L50 50 700 LC1D50A pp 30 40 ATV950D30N4/N4E GV3L65 65 910 LC1D50A pp 37 50 ATV950D37N4/N4E GV3L65 65 910 LC1D65A pp 45 60 ATV950D45N4/N4E NS80HMA 80 1000 LC1D80 pp 55 75 ATV950D55N4/N4E NSX100 p MA100 100 1040 LC1D95 pp 75 100 ATV950D75N4/N4E NSX160 p MA150 150 1500 LC1D115 pp 90 125 ATV950D90N4/N4E NSX250 p MA220 150 1500 LC1D115 pp (1) Standard power ratings for 400 V 50/60 Hz 4-pole motors. The values expressed in HP conform to the NEC (National Electrical Code). (2) For references to be completed, replace the dot with the letter corresponding to the breaking performance of the circuit breaker (F, N, H, S or L). Breaking capacity of circuit breakers according to standard IEC 60947-2: Circuit breaker Icu (kA) for 440 V F N H S L GV2L07L10 >100 GV2L14L22 50 GV3L32L65 50 NS80HMA 65 NSX100 p MA100 35 50 65 90 130 NSX160 p MA150 35 50 65 90 130 NSX250 p MA220 35 50 65 90 130 (3) Composition of contactors: LC1D09...D115: 3 poles + 1 NO auxiliary contact + 1 NC auxiliary contact To add auxiliary contacts or other accessories, please refer to the Motor-starter solutions - Control and protection components catalog. (4) Replace pp with the control circuit voltage code indicated in the table below: Volts a 24 48 110 220 230 240 LC1D09...D115 50 Hz B5 E5 F5 M5 P5 U5 60 Hz B6 E6 F6 M6 - U6 50/60 Hz B7 E7 F7 M7 P7 U7 For other voltages available between 24 V and 660 V, or a DC control circuit, please contact our Customer Care Center. (5) When used with ATV950U07N4/N4E...D90N4/N4E drives, the motor starters must be installed in a separate enclosure to maintain IP 55 protection for the installation. Presentation: page 8 References: page 18 Configuration and runtime tools: page 28 Combinations: page 32 Dimensions: page 76 NSX250 p MA220 PB103196 LC1D115 pp 105517 ATV950D90N4 PF151216A

Previous Page
Next Page