Harmony 30mm Push Buttons Page 23 9001K heavy-duty operators with chrome-plated bezels

1 2 3 4 5 6 7 8 9 10 23 Hazardous locations do not always require the use of explosion-proof equipment like the 9001BR control stations. Selecting the most appropriate device for the location can save you money. For more information on the types of hazardous locations, contact your local electrical inspector. Schneider Electric Offering According to Class, Division, and Group For Use Class Division Group(s) I 1 A 1. Intrinsically Safe System I 1 B, C, D 1. 9001BR station 2. Intrinsically Safe System I 2 A 1. 9001K control stations with restrictions (1) 2. Intrinsically Safe System I 2 B, C, D 1. 9001BR station 2. 9001K control stations with restrictions (1) 3. Intrinsically Safe System II 1 E, F, G 1. 9001BR station 2. Intrinsically Safe System II 2 E, F 1. 9001BR station 2. 9001K control stations with restrictions (1) 3. Intrinsically Safe System II 2 G 1. 9001BR station 2. 9001K control stations with restrictions (2) 3. Intrinsically Safe System III 1, 2 1. 9001BR Station 2. 9001K control stations with restrictions (2) 3. Intrinsically Safe System Any 9001K operator can be used in an area classified as Class I, Division 2 hazardous locations, if: Only logic (KA40 series) or power (KA50 series) reed contact blocks are used. All 9001K illuminated operators are UL approved for use in Class I Division 2 areas. The operators are mounted in any NEMA 4 & 13 enclosures. (1) Any 9001K operator mounted in a 9001KY, 9001KYSS, 9001KYAF or 9001SKY enclosure may be used, except potentiometer operators. (2) Add Form Y243 to single lamp Push-To-Test pilot lights. Note: For (1) and (2): UL Listed: File E10054(N), CCN NOIV. Hazardous Locations: File CCN E10054(N) NOIV File Class LR26817 3218 02 Hermetically Sealed Logic Reed Contact Blocks Suitable for use on low energy level circuits Description Symbol Reference KA41 KA42 KA43 KA44 KA45 Max. Vac/Vdc Maximum Load Resistive Inductive Continuous 32/30 .25 A .10 A .5 A 120/100 8 VA 3 VA .5 A The maximum number of logic and/or power reed contact blocks per operator is as indicated on individual selection tables for standard contact blocks, except : b On 3-Position selector switches with cams C, D, E, F, G, L, or M, mount reed blocks on one side only (either side), maximum 2 in tandem. b On 4-Position selector switches, mount reed blocks on one side only (either side), maximum 2 in tandem. b On joysticks or on 9001KR8 push-pull operators, mount reed blocks on one side only (either side), maximum 2 in tandem. Hermetically Sealed Power Reed Contact Blocks (5) Description Symbol Reference KA51 KA52 KA53 KA54 KA55 Volts AC NEMA C300 (3) Make Break Continuous Carrying Amperes A VA A VA 120 10.00 1200 1.000 120 3.0 240 5.00 .500 Volts DC NEMA Q150 (4) Make Break Continuous Carrying Amperes A VA A VA 115 .50 58 .50 58 3.0 Note: All contact blocks listed above accept #1218 solid or stranded wire. The power reed contact blocks can be used with standard industrial relays and starters through NEMA Size 4. Minimum voltage is 5 V and the minimum current is 1 mA. (3) Inductive Rating35% Power Factor. (4) Inductive and Resistive Ratings (5) Not for use in pendant stations. Harmony 9001K/SK/KX 30 mm push buttons 9001K Contact blocks References (continued) Product range: page 5 Specifications: page 7 Dimensions: page 30 Mounting: page 31 Note: When ordering, add prefix 9001 to the reference.

Previous Page
Next Page