Modicon M221 Plc Page 15 Modicon M221 and M221 Book logic controllers

2 1 3 4 5 6 7 8 9 10 2 1 3 4 5 6 7 8 9 10 15 Presentation Modicon M221 and M221 Book logic controllers Embedded communication, Characteristics Embedded communication Communication on Ethernet network TM221CE ppp and TM221ME ppp controllers have an embedded RJ 45 Ethernet port (10/100 Mbps, MDI/MDIX) with Modbus TCP (Client/Server), EtherNet/IP (adapter), UDP, TCP protocols. v As well as the default address based on the MAC address, it is possible to assign the controller IP address via a DHCP server or via a BOOTP server. v The Ethernet port also offers the same application upload/download, update and debug functions when the controller is supplied with power. v A firewall can be used to lock each communication protocol. Connection cables and accessories for Industrial Ethernet (see page 26). Serial links b Each TM221C ppp controller has an embedded serial link that can be configured as RS 232 or RS 485. A 5 V/200 mA voltage is available on the RJ 45 connector, which then supplies the TMH2GDB display unit, a Magelis XBTN or XBTRT HMI or the Bluetooth TCSWAAC13FB communication adapter. b Each TM221M ppp controller has one or two embedded serial links. v The SL1 serial link, found on each M221 Book controller, can be configured as RS 232 or RS 485. In addition, a 5 V/200 mA voltage is available on the RJ 45 connector which then supplies the TMH2GDB display unit, a Magelis XBTN or XBTRT HMI or the Bluetooth TCSWAAC13FB communication adapter or other devices. v The SL2 serial link, found on TM221M16 ppp , TM221M24 ppp and TM221M40 ppp controllers only, is configured as RS 485. Serial links also offer the same upload/download, update and debug functions when the controller is supplied with power. Embedded in both links are the two main commercially-available protocols: - Modbus ASCII/RTU Master or Slave - ASCII character string Connection cables and accessories for serial link (see page 24). Software programming with power off charging function The programming port, equipped with a USB mini-B connector, is embedded in each M221 and M221 Book controller; it is dedicated to communication with a PC equipped with SoMachine Basic for programming, debugging, and maintenance. In addition, it offers the ability to load an application program or update the irmware without the controller being powered by another source. Characteristics of M221 and M221 Book logic controllers v Certifications: e , UL Listing Mark, CSA, RCM, EAC, LR, ABS, DNV and GL (1) v Standards: IEC/EN 61131-2 (Edition 2 2007), UL 508 (UL 61010-2-201), ANSI/ISA 12.12.01-2007, CSA C22.2 No. 213, No. 142, E61131-2 and IACS E10 Environment v Ambient operating temperature: - 10...+ 55C (14...+ 131F) v Storage temperature: - 25...+ 70C (- 13...+ 158F) v Relative humidity: 10...95% (non-condensing) Operating altitude: v 0...2,000 m (0...6,562 ft.) : complete specification for temperature and insulation v 2,0004,000 m (6,56213,123 ft.): - temperature derating: + 1C/400 m (+ 1.8F/1,312 ft.) - insulation losses: 150 V c /1,000 m (150 V c /3,280 ft.) v Storage altitude: 0...3,000 m (0...9,842 ft.) v Immunity to mechanical stress (vibrations): - For 1131: 5...8.4 Hz (amplitude 3.5 mm/ 0.138 in. ); 8.4...150 Hz (acceleration 1 g) - For merchant navy: 513.2 Hz (amplitude 1.0 mm /0.039 in. ); 13.2...100 Hz (acceleration 0.7 g) Power supply Two power supply types are available depending on M221 controller model: 24 V c or 100-240 V a 50/60 Hz v Voltage limit (including ripple): 19.2...28.8 V c /85...264 V a v Immunity to micro-cuts (class PS-2): 10 ms v Max. consumption: - TM221 powered with AC, depending on model: 3141 VA without expansion modules, 4670 VA with maximum expansion module configuration - TM221 powered with DC, depending on model: 3.24.9 W without expansion modules, 1023 W with maximum expansion module configuration (1) LR, ABS, DNV and GL marine certifications: pending.

Previous Page
Next Page