Modicon M340 Plc Page 4-5 Services

4/5 Modicon M340 automation platform Standards, certifications and environment conditions Environment tests (continued) Name of test Standards Levels Immunity to mechanical constraints (1) (power on) Sinusoidal vibrations IEC/EN 61131-2; IEC 60068-2-6 (Fc) Basic IEC/EN 61131-2: 5 Hz ... 150 Hz , 3.5 mm amplitude (5 Hz . 8.4 Hz) , 1g (8.4 Hz . 150 Hz) Specific profile: 5 Hz ... 150 Hz , 10.4 mm amplitude (5 Hz . 8.4 Hz) , 3 g (8.4 Hz . 150 Hz) For basic and specific, endurance: 10 sweep cycles for each axis IACS E10 3 Hz ... 100 Hz , 1 mm amplitude (3 Hz . 13.2 Hz) , 0.7 g (13.2 Hz . 100 Hz) Endurance at each resonance frequency : 90 min for each axis , amplification coefficient < 10 IEC 60068-2-6 Sismic analysis: 3 Hz ... 35 Hz , 22.5 mm amplitude (3 Hz . 8.1 Hz) , 6 g (8.1 Hz . 35 Hz) Shocks IEC/EN 61131-2; IEC 60068-2-27 (Ea) 30 g , 11 ms; 3 shocks/direction/axis (2) 25 g , 6 ms; 100 bumps/direction/axis (bumps) (3) Free fall during operation IEC/EN 61131-2; IEC 60068-2-32 (Ed Method 1) 1 m , 2 falls Name of test Standards Levels Withstand to mechanical constraints (power off) Random free fall with packaging IEC/EN 61131-2; IEC 60068-2-32 (Method 1) 1 m , 5 falls Flat free fall IEC/EN 61131-2; IEC 60068-2-32 (Ed Method 1) 10 cm , 2 falls Controlled free fall IEC/EN 61131-2; IEC 60068-2-31 (Ec) 30 or 10 cm , 2 falls Plugging / Unplugging IEC/EN 61131-2 For modules and connectors: Operations: 50 for permanent connections , 500 for non-permanent connections Name of test Standards Levels Equipment and personnel safety (1) ( e ) Dielectric strength and insulation resistance IEC/EN 61131-2; IEC 61010-2-201; UL; CSA Dielectric: 2 Un + 1000 V; t = 1 min Insulation: Un y 50 V: 10 M!&, 50 V y Un y 250 V : 100 M!& Continuity of earth IEC/EN61131-2; IEC 61010-2-201; UL; CSA 30A , R y 0,1!&; t = 2min Leakage current UL; CSA y 3.5 mA after disconnecting Protection offered by enclosures IEC/EN 61131-2; IEC61010-2-201; IP20 and protection against standardized pins Impact withstand IEC/EN 61131-2; IEC 61010-2-201; UL; CSA Sphere of 500 g, fall from 1.30 m (energy 6.8 J minimum) Stored energy injury risk IEC/EN 61131-2; IEC 61010-2-201 Non permanent connection: 37 % Un after 1 s Permanent connection: 37 % Un after 10 s Overload IEC/EN 61131-2; IEC 61010-2-201; UL; CSA 50 cycles, Un, 1.5 In; t = 1 s ON + 9 s OFF Endurance IEC/EN 61131-2; IEC 61010-2-201; UL; CSA In, Un; 12 cycles: t=100 ms ON + 100 ms OFF, 988 cycles : t = 1 s ON + 1 s OFF, 5000 cycles : t = 1 s ON + 9 s OFF Temperature rise IEC/EN 61131-2; UL; CSA; ATEX; IECEx Ambient temperature 60 C [for ruggedized range: 70 C] (4) Name of test Standards Levels Specific Environment (1) Corrosion areas - gas, salt, dust ISAS 71.4 Mixed flowing gases: class G3 , 25 C, 75 % relative humidity, t = 14 days (4) IEC 60721-3-3 Mixed flowing gases: class 3C3 , 25 C, 75 % relative humidity, t = 14 days (4) IEC 60068-2-52 Salt spray: test Kb , severity 2 (4) (1) Devices must be installed, wired and maintained in compliance with the instructions provided in the manual Grounding and Electromagnetic Compatibility of PLC Systems. (2) In case of using fast actuators (response time y 5 ms) driven by relay outputs: 15 g , 11 ms; 3 shocks/direction/axis. (3) In case of using fast actuators (response time y 15 ms) driven by relay outputs: 15 g , 6 ms; 100 bumps/direction/axis. (4) Refer also to chapter Treatment for severe environments. ( e ) : tests required by European directives e and based on IEC/EN 61131-2 standards. Environment tests (continued) 2 1 3 4 5 6 7 8 9 10 2 1 3 4 5 6 7 8 9 10

Previous Page
Next Page