Modicon M580 Plc Page 2-22 I/O architectures

2/22 References Modicon M580 automation platform High-availability architectures References (1) Modicon M580 redundant processors Memory capacity Maximum number of networks Device ports SERVICE port Item (2) Reference Weight kg /lb 8 MB integrated (memory program) 2 Ethernet networks 2 RIO/DIO 1 1 BMEH582040 0.849/ 1.872 16 MB integrated (memory program) 4 Ethernet networks 2 RIO/DIO 1 1 BMEH584040 0.849/ 1.872 64 MB integrated (memory program) 6 Ethernet networks 2 RIO/DIO 1 1 BMEH586040 0.849/ 1.872 Accessories Description Use Cable Medium Item Reference Weight kg /lb HSBY link SFP socket (one reference for one socket) To be inserted in pair in 2 BMEH58 pp 40 redundant processors for short distance RJ45 copper 2 490NAC0100 To be inserted in pair in 2 BMEH58 pp 40 redundant processors for long distance Single- mode fiber 2 490NAC0201 Ethernet + X-bus dual power supply racks Description Type of module to be inserted Ethernet connec- tors X-bus connec- tors Power consump- tion Item (2) Reference Weight kg /lb 6-slot Ethernet + X-bus dual power supply backplane BMXCPS4002 p redundant power supply, BMEP58/BMEH58 processor, I/O modules, communication modules, and application- specific modules (counter, motion control, and serial) 4 6 3.9 W 3 BMEXBP0602 1.377/ 3.036 10-slot Ethernet + X-bus dual power supply backplane 8 10 3.9 W 3 BMEXBP1002 1.377/ 3.036 Redundancy power supply modules Line supply Available power Nominal current Item (2) Reference Weight kg /lb 3.3 V c (2) 24 V c (2) 24 V c sensors (3) Total 24 V c rack 100...240 V a 15 W 31.2 W 21.6 W 36 W 1.3 A 4 BMXCPS4002 0.360/ 0.794 100...240 V a 15 W 31.2 W 21.6 W 36 W 1.3 A 4 BMXCPS4002H 0.360/ 0.794 Ethernet network option switch Description SERVICE port Device network port (Ethernet) Item Reference Weight kg/ lb Ethernet network option switch 1 2 5 BMENOS0300 (1) For additional characteristics, see our website www.schneider-electric.com. (2) 3.3 V c and 24 V c rack voltages for powering modules in the Modicon X80 I/O rack. (3) 24 V c sensor voltage for powering the input sensors (voltage available via the 2-way removable connector on the front panel). Processors: page 1/20 Ruggedized Modicon M580 modules: page 4/2 Remote I/O architecture HMI Energy supervision HSBY communication link Altivar Process variable speed drive Ethernet Motor protection Modicon STB Modicon X80 drop Modicon M580 (Primary PLC) Modicon M580 (Standby PLC) 1 2 3 4 5 Distributed I/O architecture Energy supervision Altivar Process variable speed drive ConneXium managed switch Modicon STB HSBY communication link Modicon M580 (Primary PLC) Modicon M580 (Standby PLC) Ethernet Modicon STB 1 2 1 3 4 5 6 7 8 9 10 2 1 3 4 5 6 7 8 9 10

Previous Page
Next Page