Modicon M580 Plc Page 5-3 Standards and certifications

5/3 Environment tests Modicon M580 automation platform Standards, certifications, and environmental conditions Environment tests Name of test Standards Levels Immunity to LF interference ( e ) (1) Voltage and frequency variations IEC/EN 61131-2; IEC/EN 61000-6-2; IEC 61000-4-11 0.85...1.10 Un - 0.94...1.04 Fn; 4 steps t = 30 min IACS E10; IEC 61000-4-11 0.80 Un...0.90 Fn; 1.20 Un...1.10 Fn; t = 1.5 s/5 s Direct voltage variations IEC/EN 61131-2; IEC 61000-4-29; IACS E10 (PLC not connected to charging battery) 0.85...1.2 Un + ripple: 5% peak; 2 steps t = 30 min Third harmonic IEC/EN 61131-2 H3 (10% Un), 0/180; 2 steps t = 5 min Immunity to conducted low frequency (only IACS) IACS E10 For a : b H2H15 (10% Un), H15H100 (10%...1% Un), H100H200 (1% Un) For c : b H2H200 (10% Un) Voltage interruptions IEC/EN 61131-2; IEC/EN 61000-6-2; IEC 61000-4-11; IEC 61000-4-29; IACS E10 Power supply immunity: b 1 ms for c PS1/10 ms for a PS2 b Check operating mode for longer interruptions For IACS: b 30 s for a or c IEC/EN 61131-2; IEC/EN 61000-6-2; IEC 61000-4-11 For a PS2: b 20% Un, t0: period b 40% Un, cycle 10/12 b 70% Un, cycle: 25/30 b 0% Un, cycle 250/300 Voltage shut-down and start-up IEC/EN 61131-2 b Un0Un; t = Un/60 s b Umin0Umin; t = Umin/5 s b Umin0.9 UdlUmin; t = Umin/60 s Magnetic field IEC/EN 61131-2; IEC/TS 61000-6-5; IEC 61000-4-8 (for MV power stations: IEC 61850-3 ) Power frequency: 50/60 Hz, 100 A/m continuous ...1,000 A/m; t = 3 s; 3 axes IEC 61000-4-10 (for MV power stations: IEC 61850-3 ) Oscillatory: 100 kHz...1 MHz, 100 A/m; t = 9 s; 3 axes Conducted common mode disturbances range 0 Hz 150 kHz IEC 61000-4-16 (for MV power stations: IEC 61850-3 ) For remote systems: b 50/60 Hz and c , 300 V, t = 1s b 50/60 Hz and c , 30 V, t = 1 min b 5 Hz150 kHz, sweep 3 V30 V Where: b PS1 applies to PLC supplied by battery, PS2 applies to PLC energized from a or c supplies b Un: nominal voltage, Fn: nominal frequency, Udl: detection level when powered Name of test Standards Levels Immunity to LF interference ( e ) (1) Electrostatic discharges IEC/EN 61131-2; IEC/EN 61000-6-2; IEC 61000-4-2; IACS E10 6 kV contact; 8 kV air; 6 kV indirect contact Radiated radio frequency electromagnetic field IEC/EN 61131-2; IEC/EN 61000-6-2; IEC 61000-4-3; IACS E10 15 V/m, 80 MHz 3 GHz Sinus amplitude modulated 80%,1 kHz + internal clock frequencies Electrical fast transient bursts IEC/EN 61131-2; IEC/EN 61000-6-2; IEC 61000-4-4; IACS E10 For a or c main supplies: b 2 kV in common mode/2 kV in wire mode For a or c auxiliary supplies, a unshielded I/O: b 2 kV in common mode For analog, c unshielded I/O, communication and shielded lines: b 1 kV in common mode Surge IEC/EN 61131-2; IEC/EN 61000-6-2; IEC 61000-4-5; IACS E10 For a / c main and auxiliary supplies, a unshielded I/O: b 2 kV in common mode/1 kV in differential mode For analog, c unshielded I/O: b 0.5 kV in common mode/0.5 kV in differential mode For communication and shielded lines: b 1 kV in common mode Conducted disturbances induced by radiated electromagnetic fields IEC/EN 61131-2; IEC/EN 61000-6-2; IEC 61000-4-6; IACS E10 10 V; 0.15 MHz...80 MHz Sinus amplitude 80%, 1 kHz + spot frequencies Damped oscillatory wave IEC/EN 61131-2; IEC 61000-4-18; IACS E10 For a / c main supplies and a auxiliary supplies, a unshielded I/O: b 2.5 kV in common mode/1 kV in differential mode For c auxiliary supplies, analog, c unshielded I/O: b 1 kV in common mode/0.5 kV in differential mode For communication and shielded lines: b 0.5 kV in common mode (1) Devices must be installed, wired, and maintained in accordance with the instructions provided in the manual Grounding and Electromagnetic Compatibility of PLC Systems. (2) These tests are performed without an enclosure, with devices fixed on a metal grid and wired as per the recommendations in the manual Grounding and Electromagnetic Compatibility of PLC systems. ( e ) : Tests required by European e directives and based on IEC/EN 61131-2. 2 1 3 4 5 6 7 8 9 10 2 1 3 4 5 6 7 8 9 10

Previous Page
Next Page