Modicon M580 Plc Page 5-4 Standards and certifications

5/4 Environment tests (continued) Modicon M580 automation platform Standards, certifications, and environmental conditions Environment tests (continued) Name of test Standards Levels Electromagnetic emissions ( e ) (1) Conducted emission I EC/EN 61131-2; FCC part 15; IEC/EN 61000-6-4; CISPR 11 & 22, Class A, Group 1 150 kHz 500 kHz: quasi-peak 79 dB (V/m); average 66 dB (V/m) 500 kHz 30 MHz: quasi-peak 73 dB (V/m); average 60 dB (V/m) IACS E10 b a / c power (general power distribution zone) 10 kHz 150 kHz: quasi-peak 120...69 dB (V/m); 150 kHz 0.5 MHz: quasi-peak 79 dB (V/m) 0.5 MHz 30 MHz: quasi-peak 73 dB (V/m) b a / c power (bridge and deck zone for evaluation): 10 kHz 150 kHz: quasi-peak 9650 dB (V/m) 150 kHz 0.35 MHz: quasi-peak 6050 dB (V/m) 0.35 MHz 30 MHz: quasi-peak 50 dB (V/m) Radiated emission IEC/EN 61131-2; FCC part 15; IEC/EN 61000-6-4; CISPR 11 & 22, Class A, Group 1 30 MHz ... 230 MHz: quasi-peak 40 dB (V/m) (at 10 m) 50 dB (V/m) (at 3 m) 230 MHz ... 1 GHz: quasi-peak 47 dB (V/m) (at 10 m) 57 dB (V/m) (at 3 m) IACS E10 b For general power distribution zone 0.15 MHz 30 Mhz: quasi-peak 8050 dB (V/m) (at 3 m) 30 MHz-100 MHz: quasi-peak 6054 dB (V/m) (at 3 m) 100 MHz - 2 GHz: quasi-peak 54 dB (V/m) (at 3 m) 156 165 MHz: quasi-peak 24 dB (V/m) (at 3 m) Name of test Standards Levels Immunity to climatic variations (1) (power on) Dry heat IEC 60068-2-2 (Bb & Bd) 60 C, t = 16 hrs [for ruggedized range: 70 C, t = 16 hrs] (2) IACS E10 60 C, t = 16 hrs +70 C, t = 2 hrs [for ruggedized range: 70 C, t = 18 hrs] (2) Cold IEC 60068-2-1 (Ab & Ad) IACS E10 -25 C 0 C, t = 16 hrs + power on at 0 C [for ruggedized range: power on at -25 C] (2) Damp heat, steady state (continuous humidity) IEC 60068-2-78 (Cab); IACS E10 55 C, 93% relative humidity, t = 96 hrs [for ruggedized range: 60 C] (2) Damp heat, cyclic (cyclical humidity) IEC 60068-2-30 (Db); IACS E10 25 C 55 C, 9395% relative humidity, 2 cycles t = 12 hrs +12 hrs Change of temperature IEC 60068-2-14 (Nb) 0 C 60 C, 5 cycles t = 6 hrs + 6 hrs [for ruggedized range: -25 70 C] (2) Name of test Standards Levels Withstand to climatic variations (1) (power off) Dry heat IEC/EN 61131-2; IEC 60068-2-2 (Bb & Bd) IEC/EN 60945 85 C, t = 96 hrs Cold IEC/EN 61131-2; IEC 60068-2-1 (Ab & Ad); IACS E10 -40 C, t = 96 hrs Damp heat, cyclic (cyclical humidity) IEC/EN 61131-2; IEC 60068-2-30 (Db) 25 C 55 C, 9395% relative humidity, 2 cycles t = 12 hrs + 12 hrs Change of temperature (thermal shocks) IEC/EN 61131-2; IEC 60068-2-14 (Na) -40 C ... +85 C, 5 cycles t = 3 hrs + 3 hrs (1) Devices must be installed, wired, and maintained in accordance with the instructions provided in the manual "Grounding and Electromagnetic Compatibility of PLC Systems". (2) Refer also to the chapter "Treatment for severe environments". ( e ) : Tests required by European e directives and based on IEC/EN 61131-2 standards. 2 1 3 4 5 6 7 8 9 10 2 1 3 4 5 6 7 8 9 10

Previous Page
Next Page