Modicon M580 Plc Page 5-5 Standards and certifications

5/5 Environment tests (continued) Modicon M580 automation platform Standards, certifications, and environmental conditions Environment tests (continued) Name of test Standards Levels Immunity to mechanical constraints (1) (power on) Sinusoidal vibrations IEC/EN 61131-2; IEC 60068-2-6 (Fc) Basic IEC/EN 61131-2: 5 Hz ... 150 Hz, 3.5 mm amplitude (5 Hz . 8.4 Hz), 1 g (8.4 Hz . 150 Hz) Specific profile: 5 Hz ... 150 Hz, 10.4 mm amplitude (5 Hz . 8.4 Hz), 3 g (8.4 Hz . 150 Hz) For basic and specific: endurance: 10 sweep cycles for each axis IACS E10 3 Hz ... 100 Hz, 1 mm amplitude (3 Hz . 13.2 Hz), 0.7 g (13.2 Hz . 100 Hz) Endurance at each resonance frequency: 90 min for each axis, amplification coefficient < 10 IEC 60068-2-6 Seismic analysis: 3 Hz ... 35 Hz, 22.5 mm amplitude (3 Hz . 8.1 Hz), 6 g (8.1 Hz . 35 Hz) Shocks IEC/EN 61131-2; IEC 60068-2-27 (Ea) 30 g, 11 ms; 3 shocks/direction/axis (2) 25 g, 6 ms; 100 bumps/direction/axis (bumps) (3) EN 50155; IEC 61373 Random vibrations: 5 Hz ... 150 Hz Free fall during operation IEC/EN 61131-2; IEC 60068-2-32 (Ed Method 1) 1 m, 2 falls Name of test Standards Levels Withstand to mechanical constraints (power off) Random free fall with packaging IEC/EN 61131-2; IEC 60068-2-32 (Method 1) 1 m, 5 falls Flat free fall IEC/EN 61131-2; IEC 60068-2-32 (Ed Method 1) 10 cm, 2 falls Controlled free fall IEC/EN 61131-2; IEC 60068-2-31 (Ec) 30 or 10 cm, 2 falls Plugging/Unplugging IEC/EN 61131-2 For modules and connectors: Operations: 50 for permanent connections, 500 for non-permanent connections Name of test Standards Levels Equipment and personnel safety (1) ( e ) Dielectric strength and insulation resistance IEC/EN 61131-2; IEC 61010-2-201; UL; CSA Dielectric: 2 Un + 1000 V; t = 1 min (3000 V for PELV) Ground continuity IEC/EN 61131-2; IEC 61010-2-201; UL; CSA 30 A, R y 0,1!&; t = 2 min Leakage current UL; CSA y 3.5 mA Protection offered by enclosures IEC/EN 61131-2; IEC61010-2-201; IP20 and protection against standardized pins Impact withstand IEC/EN 61131-2; IEC 61010-2-201; UL; CSA Sphere of 500 g, fall from 1.30 m (energy 6.8 J minimum) Overload IEC/EN 61131-2; IEC 61010-2-201; UL; CSA 50 cycles, Un, 1.5 In; t = 1 s ON + 9 s OFF Endurance IEC/EN 61131-2; IEC 61010-2-201; UL; CSA In, Un; 12 cycles: 6,000 cycles: t = 1 s ON + 9 s OFF Temperature rise IEC/EN 61131-2; UL; CSA; ATEX; IECEx Ambient temperature 60 C [for ruggedized range: 70 C] (4) Name of test Standards Levels Specific environment (1) Corrosion areas - gas, salt, dust ISA S71.4 Mixed flowing gases: class G3, 25 C, 75% relative humidity, t = 14 days (4) IEC 60721-3-3 Mixed flowing gases: class 3C3, 25 C, 75% relative humidity, t = 14 days (4) IEC 60068-2-52 Salt spray: test Kb, severity 2 (4) (1) Devices must be installed, wired, and maintained in accordance with the instructions provided in the manual "Grounding and Electromagnetic Compatibility of PLC Systems". (2) When using fast actuators (response time y 5 ms) driven by relay outputs: 15 g, 11 ms; 3 shocks/direction/axis. (3) When using fast actuators (response time y 15 ms) driven by relay outputs: 15 g, 6 ms; 100 bumps/direction/axis. (4) Refer also to the chapter "Treatment for severe environments". ( e ) : Tests required by European e directives and based on IEC/EN 61131-2 standards. 2 1 3 4 5 6 7 8 9 10 2 1 3 4 5 6 7 8 9 10

Previous Page
Next Page