Preventa Safety Modules Enabling Page 2 Operating Principle / References

2 Principe, rfrences Preventa safety modules Type XPSVC For enabling switch monitoring Operating principle The enabling grip switch system, comprising an enabling switch XY2AU and a monitoring module XPSVC , enables authorised personnel to carry out adjustment, programming or maintenance operations within hazardous zones of machines providing certain conditions are met. To be accessible, such operations are often carried out at reduced speed, and must be intentionally selected by authorised persons by means of a selector switch or key switch. Once the selection is made, the enabling switch system temporarily takes over from the hazardous zone's usual protection measures. Caution: The enabling switch system alone must not cause dangerous movements of the machine to be activated; a second intentional control action on the part of the operator is required. In addition, each person remaining in the hazardous zone must be provided with an individual enabling switch to ensure their own safety. Maximum achievable safety level b PL e/Category 4 conforming to EN/ISO 13849-1 b SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061 Product certifications b UL b CSA b TV References Description Connection Number of safety circuits Solid-state outputs for PLC Supply Reference Weight kg/ lb Safety modules for enabling switch monitoring Captive screw clamp terminals Terminal block integrated in module 2 NO 2 c 24 XPSVC1132 0.250/ 0.551 Captive screw clamp terminals Terminal block removable from module 2 NO 2 c 24 XPSVC1132P 0.250/ 0.551 XPSVC1132 2 1 3 4 5 6 7 8 9 10 2 1 3 4 5 6 7 8 9 10 38726-EN version: 1.0