Preventa Safety Modules Estop Category 1 Page 7 Type XPSATE

7 Operating principle, references Preventa safety modules Type XPSATE For Emergency stop and switch monitoring Operating principle Safety modules XPSATE are used for monitoring Emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1 and also meet the safety requirements for the electrical monitoring of switches in protection devices conforming to standard EN/ISO 14119. They provide protective for both the machine operator and the machine by immediately stopping the dangerous movement on receipt of a stop instruction from the operator, or on detection of a fault in the safety circuit itself. In addition to the stop category 0 instantaneous opening safety outputs (2 for XPSATE ), the modules incorporate stop category 1 time delay outputs (3 for XPSATE ) which allow for controlled deceleration of the motor components until a complete stop is achieved (for example, motor braking by variable speed drive). At the end of the preset delay, the supply is disconnected by opening the time delay output circuits. b The time delay of the 3 output circuits is adjustable between 0 and 30 seconds using a 12-position selector switch. b Module XPSATE incorporates 4 solid-state signalling outputs for signalling to the process PLC. b To aid diagnostics, the modules have LEDs which provide information on the monitoring circuit status. b The Start button monitoring function is configurable depending on the wiring. Maximum achievable safety level b PL e/Category 4 (instantaneous safety outputs) and PL d/Category 3 (time delay safety outputs) conforming to EN/ISO 13849-1 b SILCL3 (instantaneous safety outputs) and SILCL2 (time delay safety outputs) conforming to EN/IEC 61508 and EN/IEC 62061 Product certifications b UL b CSA b TV References Description Connection Number of safety circuits Additional outputs Setting range of time delay Supply Reference Weight kg/ lb Safety modules for Emergency stop and switch monitoring Captive screw clamp terminals Terminal block integrated in module 5 NO (3 NO time delay) 4 solid-state 030 s a and c 24 V XPSATE5110 0.280/ 0.617 Captive screw clamp terminals Terminal block removable from module 5 NO (3 NO time delay) 4 solid-state 030 s a and c 24 V XPSATE5110P 0.280/ 0.617 Captive screw clamp terminals Terminal block integrated in module 5 NO (3 NO time delay) 4 solid-state 030 s a 115 V XPSATE3410 0.380/ 0.838 Captive screw clamp terminals Terminal block removable from module 5 NO (3 NO time delay) 4 solid-state 030 s a 115 V XPSATE3410P 0.380/ 0.838 Captive screw clamp terminals Terminal block integrated in module 5 NO (3 NO time delay) 4 solid-state 030 s a 230 V XPSATE3710 0.380/ 0.838 Captive screw clamp terminals Terminal block removable from module 5 NO (3 NO time delay) 4 solid-state 030 s a 230 V XPSATE3710P 0.380/ 0.838 XPSATE5110 2 1 3 4 5 6 7 8 9 10 2 1 3 4 5 6 7 8 9 10

Previous Page
Next Page