Preventa Safety Modules Time Delay Page 5 Type XPSTSW

5 Operating principle, references Preventa safety modules Type XPSTSW For safety time delays Operating principle Safety modules XPSTSW are used in applications requiring safety time delays: applications with a safety switchover contact (shunting contact in association with XPSVN modules for zero speed detection, solenoid valve monitoring, etc.). The time delay of safety circuits can be set to 16 preset values, using 2 selectors located on the front face of the modules. To aid diagnostics, the modules have LEDs which provide information on the monitoring circuit status and 2 solid-state outputs for signalling to the process PLC. In addition, their removable terminal blocks optimise machine maintenance. Maximum achievable safety level b PL d/Category 3 conforming to EN/ISO 13849-1 b SILCL 2 conforming to EN/IEC 62061 Product certifications b UL b CSA b TV References Description Connection Number of safety circuits Additional outputs / Solid-state outputs to PLC Supply Reference Weight kg/ lb Safety modules for applications with safety switchover contact Captive screw clamp terminals Terminal block removable from module 1 pulse type 2 NC / 2 a and c 24 V XPSTSW5142P 0.250/ 0.551 a 115 V XPSTSW3442P 0.360/ 0.774 a 230 V XPSTSW3742P 0.360/ 0.774 XPSTSW pppp P 2 1 3 4 5 6 7 8 9 10 2 1 3 4 5 6 7 8 9 10