Sensors Quicklook Catalog Page 22 Sensors for pressure control

Other versions: please visit our website at www.tesensors.us Sensors for pressure control Electromechanical pressure and vacuum switches XMLA and B Size: bar (psi) -.28 to -1 (-4.06 to -14.5) -0.5 to 5 (-7.25 to 72.5) 0.03 to 1 (0.435 to 14.5) 0.15 to 2.5 (2.17 to 36.25) Environmental characteristics Ambient air temperature: 13 to +158 F (25 to +70 C) , IP66: screw terminal models, IP65: connector models Rated operational characteristics (conforming to EN IEC 60947-5-1) AC-15; B300 (Ue = 240 V, Ie = 1.5 A; Ue = 120 V, Ie = 3 A) / DC-13; R300 (Ue = 250 V, Ie = 0.1 A) Product certification CE, UL, CSA, CCC, BV, LROS, RINA, GL, DNV, VIT-SEPRO, GOST Fluid connection 1/4" NPT (female) (other connections possible; consult the Customer Care Center) Electrical connection (1) Screw terminals, tapped entry for 1/2" NPT cable connector. Fluids controlled Hydraulic oils, fresh water, sea water, air up to +158 F (+70 C) Hydraulic oils, air up to +320 F (+160 C) Hydraulic oils, fresh water, sea water, air up to +158 F (+70 C) Type XMLA-fixed differential, for detection of a single threshold Setting range bar (psi) of upper limit (PH): pressure switches -0.28 to -1 (-4.06 to -14.5) (4) 0.03 to 1 (.435 to 14.5) 0.15 to 2.5 (2.17 to 36.25) Dimensions H x W x D: mm (in.) 113 x 35 x 75 (4.45 x 1.38 x 2.95) 162 x 110 x 110 (6.38 x 4.33 x 4.33) 158 x 55 x 77.5 (6.22 x 2.17 x 3.05) With setting scale 1 C/O single-pole, snap action contact XMLAM01V2S13 - XMLA001R2S13 XMLA002A2S13 Natural differential: bar (psi) at low setting 0.24 0.05 (3.48 0.72) (2) 0.02 0.01 (0.29 0.14) 0.13 0.03 (1.88 0.43) subtract from PH to give PB at high setting 0.24 0.05 (3.48 0.72) (2) 0.04 0.01 (0.58 0.14) 0.13 0.03 (1.88 0.43) Type XMLBadjustable differential, regulation between 2 thresholds Setting range bar (psi) of upper limit (PH): pressure switches -0.14 to -1 (-2.03 to -14.5) (4) -0.5 to 5 (-7.25 to 72.5) 0.05 to 1 (0.72 to 14.5) 0.3 to 2.5 (4.35 to 36.25) With setting scale 1 C/O single-pole, snap action contact XMLBM02V2S13 XMLBM05A2S13 XMLB001R2S13 XMLB002A2S13 Possible differential: bar (psi) Min. at low setting 0.13 0.02 (1.88 0.29) (3) 0.5 0.05 (7.25 0.72) 0.04 10 mbar (0.58 0.14) 0.16 -0.08 mbar +1.1 mbar (2.32 -0.01, +0.02) subtract from PH to give PB Min. at high setting 0.13 0.02 (1.88 0.29) (3) 0.5 0.05 (7.25 0.72) 0.06 20 mbar (0.87 0.29) 0.21 1.4 mbar (3.04 0.02) Max. at high setting 0.8 (11.6) (3) 6 (87) 0.75 (10.87) 1.75 (25.37) XMLC and D Fluids controlled Hydraulic oils, fresh water, sea water, air up to +158 F (+70 C) Hydraulic oils,air up to +320 F (+160 C) Hydraulic oils, fresh water, sea water, air up to +320 F (+160 C) Type XMLCadjustable differential, regulation between 2 thresholds Setting range bar (psi) of upper limit (PH): pressure switches -0.14 to -1 (-2.03 to -14.5) (4) -0.55 to 5 (-7.97 to 72.5) 0.05 to 1 (0.725 to 14.5) 0.3 to 2.5 (4.35 to 36.25) Dimensions (mm) H x W x D 158 x 55 x 90 150 x 110 x 110 145 x 55 x 90 With setting scale 2 C/O single-pole, snap action contacts XMLCM02V2S13 XMLCM05A2S13 XMLC001R2S13 XMLC002B2S13 Possible differential: bar (psi) Min. at low setting 0.13 0.02 (1.89 0.29) (4) 0.45 0.1 (6.52 1.45) 0.03 0.01 (0.43 0.14) 0.13 0.02 (1.89 0.29) subtract from PH to give PB Min. at high setting 0.14 0.02 (2.03 0.29) (4) 0.45 0.1 (6.52 1.45) 0.04 0.03 (0.58 0.43) 0.17 0.03 (2.47 0.43) Max. at high setting 0.8 (11.6) (4) 6 (87) 0.8 (11.6) 2 (29) Type XMLD-fixed differential, dual stage, for detection at each threshold Setting range bar (psi) 2 nd stage switching point (PB2) -0.12 to -1 (-1.74 to -14.5) (4) 0.12 to 1 (1.74 to 14.5) 0.34 to 2.5 (4.93 to 36.25) 1 st stage switching point (PB1) -0.10 to -0.98 (-1.45 to -14.21) 0.04 to 0.92 (0.58 to 13.34) 0.2 to 2.36 (2.90 to 34.22) Spread between 2 stages (PB2 PB1) -0.02 to -0.88 (0.29 to 12.76) 0.08 to 0.73 (1.16 to 10.59) 0.14 to 1.5 (2.03 to 21.75) Without setting scale 2 C/O single-pole, snap action contacts (1 per stage) XMLDM02V1S13 - XMLD001R1S13 XMLD002B1S13 Natural differential: bar (psi) at low setting 0.1 0.035 (1.45 0.51) (2) 0.03 0.01 (0.44 0.14) 0.14 0.04 (2.03 0.58) subtract from PH 1/2 to give PB 1/2 at high setting 0.1 0.02 (1.45 0.29) (2) 0.07 0.04 (1.02 0.58) 0.19 0.07 (2.76 1.02) XMLD XMLC OsiSense XM (1) For electrical connection by DIN 43650A connector (IP65), replace the suffix S13 in the catalog number with C11 . Example: XMLB010A2 S13 becomes XMLB010A2 C11 . (2) For vacuum switch: natural differential to be added to PB to give PH. (3) For vacuum switch: possible differential to be added to PB to give PH. (4) Setting range bar (psi) of lower limit (PB): vacuum switch. 12 11 13 14 22 21 23 24 12 11 13 14 22 21 23 24 12 11 13 14 1 C/O single-pole contact, snap action 2 C/O single-pole contacts, simultaneous snap action 2 C/O single-pole contacts, snap action (1 per stage) 22

Previous Page
Next Page