Square D General Purpose Relays Miniature Relays Page 4 Specifications

4 Socket specifications Socket type 8501NR45 RXZE2S114S Relay types used 8501RS(D)14 ppp 8501RS(D)24 ppp 8501RS(D)34 ppp 8501RS(D)14 ppp 8501RS(D)24 ppp 8501RS(D)34 ppp Contact terminal arrangement Separate Wire connection method Screw clamp terminals Spring clamp terminals Product certifications cURus File E66924 CCN SWIV2, SWIV8; CSA; CE; RoHS compliant cURus File E172326 CCN SWIV2, SWIV8; CSA; CE; RoHS compliant Conforming to standards IEC 61984, UL 508, CSA 22.2 No. 14 Electrical specifications Conventional thermal current (Ith) A 10 at 300 Vac (UL) 6 at 250 Vac (UL / IEC) Insulation specifications Between adjacent output contacts Vrms 2000 2500 Between input and output contacts Vrms 2000 2500 Between contacts and DIN rail Vrms 2000 2500 General specifications Ambient air temperature around the device StorageC(F) - 40 to + 85 (- 40 to + 185) OperationC(F) - 40 to + 55 (- 40 to + 131) Degree of protection Conforming to IEC/EN 60529 IP 20 Connection Solid wire without cable end 1 conductor 0.5 to 2.5 mm 2 - AWG 20 to AWG 14 0.5 to 1.5 mm 2 AWG 20 to AWG 16 2 conductors 0.5 to 2.5 mm 2 - AWG 20 to AWG 14 Flexible wire with cable end 1 conductor 0.5 to 2.5 mm 2 - AWG 20 to AWG 14 0.5 to 1.5 mm 2 AWG 20 to AWG 16 2 conductors 0.5 to 2.5 mm 2 - AWG 20 to AWG 14 0.5 to 1.5 mm 2 AWG 20 to AWG 16 Maximum tightening torque / Screw size Lb-ft (Nm) 0.6-0.7 (0.8-1) / M3 screw - Mounting On 35 mm DIN rail / on panel Mounting on DIN rail By plastic clip By metal compression spring Terminal referencing IEC, NEMA Compatible with hold down clip Yes No Compatible with restraining strap Yes No Wire connection method Screw clamp terminals Spring clamp terminals Square D General Purpose Relays Class 8501R miniature control relays Specifications (continued) Coil specifications 8501RS14 ppp , 8501RS24 ppp , 8501RSD14 ppp , 8501RSD24 ppp 8501RS34 ppp , 8501RSD34 ppp Average consumption AC VA 0.9-1.2 DC W 0.8-1.1 Drop-out voltage threshold AC u 0.15 Uc u 0.3 Uc DC u 0.1 Uc u 0.1 Uc Response time Operate time AC ms 20 (max.) DC ms 20 (max.) Release time AC ms 20 (max.) DC ms 20 (max.) Control circuit voltage Uc V 6 12 24 48 110 120 240 6 12 24 48 110 120 240 Relay control voltage codes V51 V53 V56 V60 V50 V51 V53 V56 V60 DC supply Average resistance at 20 C 10% W 160 650 2560 13440 - 40 160 650 2600 11000 - Operating voltage limits Min. Vdc 9.6 19.2 38.4 88 - - 4.5 9 18 36 82.5 - - Max. Vdc 13.2 26.4 52.8 121 - - 6.6 13.2 26.4 52.8 121 - - Relay control voltage codes V14 V17 V20 V24 V35 V36 V14 V17 V20 V24 AC supply Average resistance at 20 C 15% W - 177 708 - 3630 17720 10.5 43 160 668 - 3900 9100 Operating voltage limits Min. Vac - 19.2 38.4 - 96 192 4.8 9.6 19.2 38.4 - 96 192 Max. Vac - 26.4 52.8 - 132 264 6.6 13.2 26.4 52.8 - 132 264

Previous Page
Next Page