Square D General Purpose Relays Plug IN Relays Page 4 Specifications

4 Socket specifications Socket type 8501NR41 8501NR42 8501NR43 8501NR44 Relay types used 8501RS41 ppp 8501RSD41 ppp 8501RS42 ppp 8501RSD42 ppp 8501RS43 ppp 8501RSD43 ppp 8501RS44 ppp 8501RSD44 ppp Contact terminal arrangement Separate Wire connection method Screw clamp terminals Product certifications cURus File E66924 CCN SWIV2, SWIV8; CSA; CE; RoHS compliant Conforming to standards IEC 61984, UL 508, CSA 22.2 No. 14 Electrical specifications Conventional thermal current (Ith) A 15 at 300 Vac (UL) 10 at 300 Vac (UL) Insulation specifications Between adjacent output contacts Vrms 2000 Between input and output contacts Vrms 2000 Between contacts and DIN rail Vrms 2000 General specifications Ambient air temperature around the device StorageC(F) - 40 to + 85 (- 40 to + 185) OperationC(F) - 40 to + 55 (- 40 to + 131) Degree of protection Conforming to IEC/EN 60529 IP 20 Connection Solid wire without cable end 1 conductor 1.5 mm 2 - AWG 16 2 conductors 0.75 mm 2 - AWG 18 Flexible wire with cable end 1 conductor 1.5 mm 2 - AWG 16 2 conductors 0.75 mm 2 - AWG 18 Maximum tightening torque / Screw size Lb-ft (Nm) 9 (1.0) / M3.5 screw Mounting On 35 mm DIN rail / on panel Mounting on DIN rail By plastic clip Terminal referencing IEC, NEMA Compatible with hold down clip Yes Compatible with restraining strap No Wire connection method Screw clamp terminals Square D General Purpose Relays Class 8501R plug-in relays Specifications (continued) Coil specifications 8501RS41 ppp 8501RSD41 ppp 8501RS42 ppp 8501RSD42 ppp 8501RS43 ppp 8501RSD43 ppp 8501RS44 ppp 8501RSD44 ppp Average consumption (1) AC VA 1.6 1.1 1.7 2.5 DC W 1.1 0.85 1.5 1.6 Average consumption with LED (1) AC VA 1.9 1.4 2.05 2.85 DC W 1.4 1.15 1.85 1.95 Drop-out voltage threshold AC VA e 0.15 Uc DC W e 0.10 Uc Response time Operate time (at 100% Uc) AC ms 20 (max.) DC ms 20 (max.) Release time (at 100% Uc) AC ms 20 (max.) DC ms 20 (max.) Control circuit voltage Uc V 12 24 110 120 240 Relay control voltage codes V51 V53 V60 DC supply Average resistance at 20 C 10% 8501RSD41 W 115 450 9460 8501RSD42 W 160 640 13440 8501RSD43 W 80 320 6720 8501RSD44 W 75.8 303 6370 Operating voltage limits Min. Vdc 9.6 19.2 88 Max. Vdc 13.2 26.4 121.0 Relay control voltage codes V36 V14 V20 V24 AC supply Average resistance at 20 C 15% 8501RS41 W 44 177 4430 17720 8501RS42 W 44 177 4430 17720 8501RS43 W 30 110 2880 11300 8501RS44 W 20 80 2100 8000 Operating voltage limits Min. Vac 9.6 19.2 96 192 Max. Vac 13.2 26.4 132 264 (1) Average consumption tolerance for 8501RS(D)41, 43 and 44 is +10% / -20%; average consumption tolerance for 8501RS(D)42 is +10% / -25%.

Previous Page
Next Page